Compare

Side by side.

Every value is from that model's spec sheet or drawing. "We confirm" means the maker's documents disagree; "not stated" means the value is not in yet. Your quote states both.

Showing every model. Pick up to four on the displays page to compare just those.

Field10.1 in wall displayIMDS-W101-A15.6 in wall displayIMDS-W156-A15.6 in wall displayIMDS-W156-B15.6 in wall displayIMDS-W156-C15.6 in slim wall displayIMDS-WS156-E15.6 in wall displayIMDS-W156-F18.5 in slim wall displayIMDS-WS185-D21.5 in wall displayIMDS-W215-A32 in wall displayIMDS-W32-A32 in wall displayIMDS-W32-B43 in wall displayIMDS-W43-B55 in wall displayIMDS-W55-A55 in wall displayIMDS-W55-B37 in stretched bar displayIMDS-SB37-B55 in floor totemIMDS-FT55-B8 in dual-screen table playerIMDS-TPD8-D8 in battery table playerIMDS-TPB8-D15.6 in desk display with kickstandIMDS-DK156-E15.6 in desk displayIMDS-DS156-F15.6 in pole-mount displayIMDS-PM156-F
MountWallWallWallWallWallWallWallWallWallWallWallWallWallStretched barFloor-standingTable topTable topDesk and counterDesk and counterPole and rail
Display
Screen size10.1 in15.6 in15.6 in15.6 in15.6 in15.6 in18.5 in21.5 in32 in32 in43 in55 in55 in37 in55 in8 in8 in15.6 in15.6 in15.6 in
PanelNot statedTFT-LCD; 16.7M coloursTFT LCD, grade A+, WLED backlight, 16.7M colours (8-bit)LCD, ELED backlight, 1.07B colours (10-bit), pixel pitch 0.372 x 0.372 mm15.6" high-definition full view screenLCD, normally blackIPS, normally blackNot statedNot statedTFT LCD, grade A+, WLED backlight, 16.7M colours (8-bit)TFT LCD, grade A+, WLED backlight, 16.7M colours (8-bit)Not statedTFT LCD, grade A+, WLED backlight, 16.7M colours (8-bit)Professional-grade LCDIPS, 178 deg viewing, 16.7M coloursTFT LCDTFT LCD15.6" high-definition full view screenLCDNot stated
ResolutionNot stated1920 × 10801920 × 10801920 × 10801920 × 10801920 × 10801920 × 1080Not statedNot stated1920 × 10801920 × 1080Not statedWe confirmNot statedNot statedWe confirm800 × 12801920 × 10801920 × 1080Not stated
Aspect ratioNot stated16:916:916:916:916:916:9Not statedNot stated16:916:9Not stated16:9Not stated9:16 portrait (screen window 678.4 W x 1207.6 H)10:16 portrait10:16 portrait16:9Not statedNot stated
BrightnessNot stated250 nits300 nits250 nits300 nits250 nitsNot statedNot statedNot stated300 nits450 nitsNot stated450 nitsNot statedNot statedWe confirm250 nits300 nits250 nitsNot stated
ContrastNot stated1500:1≥800:1800:11000:18001200:1Not statedNot stated≥1200:1≥1200:1Not stated≥1200:1Not statedNot statedNot statedNot stated1000:1800Not stated
Viewing angleNot stated89/89/89/89° (up/down/left/right)178/178°85/85/85/85°85/85/85/85° (L/R/U/D)85/85/85/85° (L/R/U/D)178/178/178/178° (L/R/U/D)Not statedNot stated178/178°178/178°Not stated178/178°Not stated178°Not statedNot stated85/85/85/85° (L/R/U/D)85/85/85/85° (L/R/U/D)Not stated
Response timeNot stated8 ms8 ms8 msNot statedNot statedNot statedNot statedNot stated8 ms8 msNot stated8 msNot statedNot statedNot statedNot statedNot statedNot statedNot stated
Refresh rateNot stated50/60 HzNot stated60 HzNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot stated
TouchNot statedNo touch; touch can be addedNo touchNo touchNo touchCapacitive 10-pointNo touchNot statedNot statedNo touchNo touchNot statedNo touchNo touch; 10-point capacitive touch optionalNo touch; 10-point capacitive touch optionalCapacitive 5-point, dual touch panelsCapacitive 5-point (10-point optional)No touchCapacitive 10-pointNot stated
Front glassNot statedNot statedTempered glass, 3 mmNot statedNot statedNot statedNo cover glassNot statedNot statedTempered glass, 3 mmTempered glass, 3 mmNot statedTempered glass, 3 mmNot statedTempered glass protectionNot statedNot statedNot statedNot statedNot stated
Double-sidedNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoYesNoNoNoNot stated
Computer
Operating systemNot statedAndroid 11.0We confirmAndroid 13.0Android 10Android 13Android 11.0Not statedNot statedAndroid 9/11 (optional)Android 9/11 (optional)Not statedAndroid 6/7/9/11 (optional)AndroidAndroid (Windows optional)Android 11Android 11Android 10Android 8.1Not stated
ProcessorNot statedRK3566SRK3566SA527A133RK3568RK3566 (RK3568 optional)Not statedNot statedWe confirmWe confirmNot statedWe confirmNot statedNot statedRK3568 (22 nm)RK3566A133RK3288Not stated
CPUNot statedQuad-coreNot statedOcta-core Cortex-A55, 1.8 GHzQuad-core 64-bit Cortex-A53Quad-core Cortex-A55Not statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedQuad-core 64-bit Cortex-A55, up to 2.0 GHzQuad-core 64-bit Cortex-A55, max 1.8 GHzQuad-core 64-bit Cortex-A53Quad-core Cortex-A17Not stated
GraphicsNot statedNot statedNot statedARM Mali-G57 MC01Not statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedARM G52 2EEARM G52 2EENot statedNot statedNot stated
Memory (RAM)Not stated2 GB2 GB2 GB2 GB2 GB2 GBNot statedNot stated2 or 4 GB (optional)2 or 4 GB (optional)Not stated1, 2 or 4 GB (optional)Not statedNot stated4 GB2 or 4 GB (LPDDR4)2 GB2 GBNot stated
StorageNot stated32 GB32 GB32 GB16 GB16 GB32 GBNot statedNot stated16, 32 or 64 GB (optional)16, 32 or 64 GB (optional)Not stated16, 32 or 64 GB (optional)Not statedNot stated32 GB32 GB16 GB16 GBNot stated
Storage expansionNot statedNot statedMicroSD card slot x1MicroSD card slot x1MicroSD card slotSD card up to 32 GBMicroSD card x1, up to 64 GBNot statedNot statedMicroSD card slot x1MicroSD card slot x1Not statedMicroSD card slot x1USB stick / SD card offline playbackSD card, USB 2.0 hard disk, USB stickNot statedMicroSD card up to 128 GBMicroSD card slotMicroSD card slotNot stated
Connections
EthernetNot statedYesRJ45 x1, 10/100/1000 MbpsRJ45 x1100 Mbps RJ45 (PoE optional)10/100/1000 Mbps RJ4510/100 Mbps RJ45 x1Not statedNot statedRJ45 x1, 10/100/1000 MbpsRJ45 x1, 10/100/1000 MbpsNot statedRJ45 x1, 10/100/1000 MbpsNot statedLANNot statedNot stated100 Mbps RJ45 (PoE optional)RJ45 10/100 Mbps, PoENot stated
Wi-FiNot statedWi-FiWi-Fi, 2.4 GHzWe confirmWi-Fi, 2.4 GHzWi-Fi, 2.4 GHzWi-Fi, 2.4 GHzNot statedNot statedWi-Fi, 2.4 GHzWi-Fi, 2.4 GHzNot statedWi-Fi, 2.4 GHzWi-FiWi-FiWi-Fi, 2.4 and 5 GHzWi-Fi, 2.4 and 5 GHzWi-Fi, 2.4 GHzWi-Fi, 2.4 GHzNot stated
BluetoothNot statedNot statedBluetooth 4.0Bluetooth 5.4, built-inBT 5.2Bluetooth 4.0Bluetooth 4.0Not statedNot statedBluetooth 4.0Bluetooth 4.0Not statedBluetooth 4.0Not statedNot statedDual-mode Bluetooth 5.0Dual-mode Bluetooth 5.0BT 5.2Not statedNot stated
CellularNot statedNone; 4G can be addedOptional 4G modem; SIM card slot x1 (needs the 4G modem)Not stated4G/5G optionalNot statedNot statedNot statedNot statedOptional 4G modem; SIM card slot x1 (needs the 4G modem)Optional 4G modem; SIM card slot x1 (needs the 4G modem)Not statedOptional 4G modem; SIM card slot x1 (needs the 4G modem)Not statedNot stated4G optional; 100 Mbps down / 50 Mbps up; SIM card port4G optional (100 Mbps down / 50 Mbps up)4G/5G optionalNot statedNot stated
PortsNot statedWe confirmWe confirmWe confirmWe confirmSD card slot, Mini USB (OTG), 1x USB 3.0 host, 2x USB 2.0 host, DC power input, RJ45 Ethernet, HDMI output, 3.5 mm earphoneHDMI output x1 (on the RK3568 board: HDMI input x1 instead), microSD card x1, USB x2 (1 host, 1 OTG), RJ45 x1, 3.5 mm stereo earphone out x1, AC power cord (built-in, 1.8 m)Not statedNot statedHDMI out x1 (HDMI input only with the T972 board option), 3.5 mm headphone/audio out x1, USB x2, microSD card slot x1, SIM card slot x1 (needs optional 4G modem), RJ45 x1 (10/100/1000), DC power x1HDMI out x1 (HDMI input only with the T972 board option), 3.5 mm headphone/audio out x1, USB x2, microSD card slot x1, SIM card slot x1 (needs optional 4G modem), RJ45 x1 (10/100/1000), DC power x1Not statedHDMI out x1 (HDMI input only with the T972 board option), 3.5 mm headphone/audio out x1, USB x2, microSD card slot x1, SIM card slot x1 (needs optional 4G modem), RJ45 x1 (10/100/1000), DC power x1Not statedNot stated1x Micro USB 2.0 OTG (USB stick), 1x 4G SIM card port, USB-A output 5V/2A (phone charging), USB-C output 5V/2A (phone charging), DC input1x Micro USB 2.0 / USB 3.0 OTG (USB stick), microSD card slot, DC input, phone-charging outputs: built-in 3-in-1 cable (Lightning / Micro USB / USB-C) plus USB port(s)We confirmRJ45 (PoE), USB, microSD card, serial port, micro USB / OTG, earphone, DC inNot stated
SpeakersNot statedStereo2 x 3 W, 8 ohm2 channels, 2 x 5 W, 8 ohm2x 3 W2x 2 W4 ohm 2 WNot statedNot stated2 x 5 W, 8 ohm2 x 5 W, 8 ohmNot stated2 x 5 W, 8 ohmNot stated2 x 5 W1x 8 ohm / 1 W1x 8 ohm / 1 W2x 3 W2x 2 WNot stated
MicrophoneNot statedNot statedNot statedNot stated1 microphoneYesNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNoNot stated1 microphoneNot statedNot stated
CameraNot statedNot statedNot statedNot stated2.0 MP, standardFront cameraNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedOptional, 2 MP (max 5 MP)2.0 MP, standardFront cameraNot stated
NFCNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedOptionalNot statedNot statedNot stated
SensorsNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedMotion sensor: detects people, screen auto-onMotion radar sensor, motion induction within 3 mNot statedNot statedNot stated
Power
Power inputNot statedWe confirmWe confirmWe confirmDC 5.5x2.1 jack; external adapter 12V/2AExternal adapter 12V/3A; DC inputNot statedNot statedNot statedWe confirmWe confirmNot statedWe confirmNot statedNot statedWe confirm12V / 2A DC adapterDC 5.5x2.1 jack; external adapter 12V/2ADC power input; PoENot stated
Power drawNot stated≤35 W (max); standby <1≤25 W (max)≤60 max W; standby ≤1Not statedNot stated≤18 WNot statedNot stated≤65 W (max)≤85 W (max)Not stated≤110 W (max)Not statedNot statedNot statedNot statedNot statedNot statedNot stated
BatteryNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot stated12x 2900 mAh 18650 Li-ion, 34800 mAh total; detachable (battery base and screen part separate)8x 2900 mAh 18650 (2S4P), 23200 mAh total, detachable; runs on the adapter without the batteryNot statedNot statedNot stated
Wireless chargingNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot stated2x 15 W wireless phone chargers (one per face)Not statedNot statedNot statedNot stated
Size and mounting
Outside, W × H × DWe confirm376.4 × 236.4 × 52.2 mmWe confirmWe confirm375.5 × 225 × 28 mm388 × 245 × 27 mmNot stated508.4 × 305 × 50.8 mmWe confirmWe confirmWe confirm1264.5 × 743.5 × 83.9 mmWe confirm932 × 285 mm, width × height (depth we confirm)We confirmWe confirmNot stated375.5 × 225 × 28 mm389.16 × 242.92 mm, width × height (depth we confirm)Not stated
Depth without bracket36 mm42.2 mm46.2 mmNot statedNot statedNot statedNot stated40.8 mm54.2 mm58.8 mm68.5 mm68.9 mm68.3 mmNot statedNot statedNot statedNot statedNot statedNot statedNot stated
DepthNot statedNot statedNot statedNot statedNot statedNot stated23.02 mmNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot stated
Active areaNot stated344.16 × 193.59 mm344.16 × 193.59 mm344.16 × 193.59 mm344 × 194 mmNot stated408.96 × 230.04 mmNot statedNot stated698.4 × 392.85 mm940.896 × 529.254 mmNot stated1209.6 × 680.4 mmNot statedNot statedNot statedNot stated344 × 194 mmNot statedNot stated
Visible window216.58 × 135.36 mm344.16 × 193.59 mm342.16 × 191.59 mm343 × 192 mmNot stated347 × 195 mmNot stated476.5 × 268 mm698 × 391.8 mm697.6 × 392.85 mm939.2 × 527.4 mm1209.6 × 680.4 mm1207.6 × 678.4 mmNot statedWe confirmNot statedNot statedNot statedNot statedNot stated
VESA pattern75 × 75 mm100 × 100 mm100 × 100 mm100 × 100 mm100 × 100100 × 100100 × 100, 4x M4100 × 100 mm (bracket holes 144.22 x 106)400 × 200 mm (bracket 454.06 wide)400 × 300 mm (keyholes)400 × 400 mm (keyholes)400 × 400 mm (bracket 454.06 wide)400 × 400 mm (keyholes)Not statedNot statedNot statedNot stated100 × 100Not statedNot stated
MountingWall mount (rear bracket)Wall (standard VESA holes), landscape or portrait; can also be used on a desk standWall-mount bracket on VESA 100x100; landscape or portraitWall-mount bracket (VESA)Wall (VESA 100 x 100); a desktop bracket is also includedWall via VESA 100; desk via the included stand (screw-in kickstand rod into a rear socket)Flush wall mount on the included ultra-thin wall plate, 2 mm from the wall; landscape or portrait; optional recessed (embedded) install; optional mobile stand with rotation and height adjustmentWall mount (rear bracket)Wall mount (rear bracket)Wall mount, landscape or portraitWall mount, landscape or portraitWall mount (rear bracket)Wall mount, landscape or portraitNot statedFloor-standing on its own baseTabletop (free-standing)Tabletop L-shape; optional anti-theft lock plate for fixing to a deskDesk on the included desktop bracket (kickstand); wall by the VESA 100 insertsDesk, fixed L-standPole with clamp box and articulated arm on a base plate
Net weightNot statedNot statedAround 3 kg3 kgNot stated1.45 kgNot statedNot statedNot statedAround 14 kgAround 24.5 kgNot statedAround 37 kgNot statedNot stated1.41 kg1 kgNot statedNot statedNot stated
Shipping weightNot statedNot statedAround 4 kg (excluding wooden case)4 kgNot stated2.45 kg (in gift box)Not statedNot statedNot statedAround 15.5 kg (excluding wooden case)Around 26 kg (excluding wooden case)Not statedAround 39 kg (excluding wooden case)Not statedNot statedNot statedNot statedNot statedNot statedNot stated
EnclosureNot statedAluminium metal frameNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedSheet-metal back cover; ultra thinNot statedFire-resistant ABSNot statedNot statedNot stated
ColourNot statedNot statedBlack, white or silver (optional)Not statedNot statedNot statedBlackNot statedNot statedBlack, white or silver (optional)Black, white or silver (optional)Not statedBlack, white or silver (optional)Not statedNot statedBlack / Wood GrainBlack / WhiteNot statedNot statedNot stated
Environment
Operating temperatureNot stated0 to 45°C0 to +50°C0 to 40°C0 to 50°C0 to 40°C0 to 50°CNot statedNot stated0 to +50°C0 to +50°CNot stated0 to +50°CNot statedNot statedNot statedNot stated0 to 50°CNot statedNot stated
Storage temperatureNot stated-20 to 60°CNot stated-20 to 60°CNot statedNot stated-10 to +60°CNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot statedNot stated
HumidityNot statedOperating 10-90 %Working 10-85 %RH; storage 10-85 %RHWorking 10-90 %RH; storage 10-90 %RHNot statedNot stated≤80% RHNot statedNot statedWorking 10-85 %RH; storage 10-85 %RHWorking 10-85 %RH; storage 10-85 %RHNot statedWorking 10-85 %RH; storage 10-85 %RHNot statedNot statedNot statedNot statedNot statedNot statedNot stated
QuoteAskAskAskAskAskAskAskAskAskAskAskAskAskAskAskAskAskAskAskAsk