Desk display with kickstand · series E

15.6 in desk display with kickstand

Model IMDS-DK156-E

  • Resolution1920 × 1080
  • Brightness300 nits
  • TouchNo touch
  • Operating systemAndroid 10
  • Power inputDC 5.5x2.1 jack; external adapter 12V/2A

Sold by quote. Your quote states the price, lead time and warranty in writing.

15.6-inch desk display with kickstand, hero dark view. 3D render with sample screen artwork.15.6-inch desk display with kickstand, hero light view. 3D render with sample screen artwork.
3D render from the product CAD, sample artwork on the screen.

Every side

Front, back, corners and connectors.

Rendered from this model's CAD with our sample artwork. Select a picture to see it full size.

On our studio set

Photographs of the product, restaged on our set with our artwork on the screen.

Rear view of a black display lying flat, with a raised back housing, speaker grille, mounting holes and fine ribbed panel. Rear view of a large black tablet-style display with speaker grilles, a green indicator light and a silver fold-out stand. Rear view of a black landscape display with two speaker grilles, mounting holes, green sticker and a white loop stand. Rear side view of a black thin display on a tilted silver stand, with a raised back housing and green sticker. Side profile of a thin black display tilted back on a slim silver kickstand, with a small back housing.

In 3D

Turn it. Take it apart.

The model is this product's CAD, simplified for the browser. Drag to turn it, pinch or Ctrl and scroll to zoom, or use the arrow keys. Separate the parts to see how the front, the panel and the rear housing go together.

Screen in the model: 344.2 × 193.6 mm. Ports, buttons and vents follow the maker's drawings; use the dimension drawing for anything you cut or fix.

Specification

What the spec sheet says.

Every value below is from this model's spec sheet or drawing. Where two of the maker's documents disagree, we show "we confirm with your quote" rather than pick one.

Resolution
1920 × 1080
Brightness
300 nits
Touch
No touch
Operating system
Android 10
Power input
DC 5.5x2.1 jack; external adapter 12V/2A
Outside, W × H × D
375.5 × 225 × 28 mm

Display

9
Screen size
15.6 in
Panel
15.6" high-definition full view screen
Resolution
1920 × 1080
Aspect ratio
16:9
Brightness
300 nits
Contrast
1000:1
Viewing angle
85/85/85/85° (L/R/U/D)
Touch
No touch
Double-sided
No

Computer

6
Operating system
Android 10
Processor
A133
CPU
Quad-core 64-bit Cortex-A53
Memory (RAM)
2 GB
Storage
16 GB
Storage expansion
MicroSD card slot

Connections

8
Wi-Fi
Wi-Fi, 2.4 GHz
Bluetooth
BT 5.2
Ethernet
100 Mbps RJ45 (PoE optional)
Cellular
4G/5G optional
Ports
We confirm with your quote
Speakers
2x 3 W
Microphone
1 microphone
Camera
2.0 MP, standard

Power

1
Power input
DC 5.5x2.1 jack; external adapter 12V/2A

Size and mounting

4
Outside, W × H × D
375.5 × 225 × 28 mm
Active area
344 × 194 mm
VESA pattern
100 × 100
Mounting
Desk on the included desktop bracket (kickstand); wall by the VESA 100 inserts

Environment

1
Operating temperature
0 to 50°C

Listed in the box

  • User manual
  • Desktop bracket
  • Adapter 12V/2A

From the maker's packing list. We confirm what ships with your quote.

Confirmed with your quote

  • Price and quantity breaks
  • Lead time from your order
  • Warranty terms, in writing
  • Anything marked "we confirm" above

Not rated for outdoor use. Need touch, a different brightness or another option? Say so in the quote.

Install

Setting up a desk or counter display.

Desk displays stand on their own base or kickstand, on a reception desk, a counter or a meeting room table. Set the angle, route the cable and load content.

Install film for this model: 3d animation from the product cad, sample artwork. No sound; every step is written out below, and pressing a step plays from there.

  1. 01

    Open the kickstand

    Swing the kickstand out from the back of the display.

  2. 02

    Stand it up

    Set the display down on a flat, steady surface near a power outlet.

  3. 03

    Connect power

    Connect the power cable between the display and the outlet.

  4. 04

    Add your content

    Insert the microSD card or USB stick with your pictures and videos.

  5. 05

    Power on

    Switch on the power and the screen lights up.

The full guide, with the 3D walkthrough About 15 minutes. One person.

Where it goes

Screens like this, at work.

Example applications of this kind of screen. These are not our customers' sites, and the screens in them may be other models.

Compare

Close relatives.

See these side by side

Quote the 15.6 in desk display with kickstand.

Tell us how many, where they go and how they get power. We reply by email with the price, lead time and warranty in writing.