Wall display · series C

15.6 in wall display

Model IMDS-W156-C

  • Resolution1920 × 1080
  • Brightness250 nits
  • TouchNo touch
  • Operating systemAndroid 13.0
  • Power inputWe confirm with your quote

Sold by quote. Your quote states the price, lead time and warranty in writing.

15.6-inch wall-mount signage display, hero dark view. 3D render with sample screen artwork.15.6-inch wall-mount signage display, hero light view. 3D render with sample screen artwork.
3D render from the product CAD, sample artwork on the screen.

Every side

Front, back, corners and connectors.

Rendered from this model's CAD with our sample artwork. Select a picture to see it full size.

In 3D

Turn it. Take it apart.

The model is this product's CAD, simplified for the browser. Drag to turn it, pinch or Ctrl and scroll to zoom, or use the arrow keys. Separate the parts to see how the front, the panel and the rear housing and the wall bracket go together.

Screen in the model: 344.2 × 193.6 mm. Ports, buttons and vents follow the maker's drawings; use the dimension drawing for anything you cut or fix.

Specification

What the spec sheet says.

Every value below is from this model's spec sheet or drawing. Where two of the maker's documents disagree, we show "we confirm with your quote" rather than pick one.

Resolution
1920 × 1080
Brightness
250 nits
Touch
No touch
Operating system
Android 13.0
Power input
We confirm with your quote
Outside, W × H × D
We confirm with your quote

Display

11
Screen size
15.6 in
Panel
LCD, ELED backlight, 1.07B colours (10-bit), pixel pitch 0.372 x 0.372 mm
Resolution
1920 × 1080
Aspect ratio
16:9
Brightness
250 nits
Contrast
800:1
Viewing angle
85/85/85/85°
Response time
8 ms
Refresh rate
60 Hz
Touch
No touch
Double-sided
No

Computer

7
Operating system
Android 13.0
Processor
A527
CPU
Octa-core Cortex-A55, 1.8 GHz
Graphics
ARM Mali-G57 MC01
Memory (RAM)
2 GB
Storage
32 GB
Storage expansion
MicroSD card slot x1

Connections

5
Wi-Fi
We confirm with your quote
Bluetooth
Bluetooth 5.4, built-in
Ethernet
RJ45 x1
Ports
We confirm with your quote
Speakers
2 channels, 2 x 5 W, 8 ohm

Power

2
Power input
We confirm with your quote
Power draw
≤60 max W; standby ≤1

Size and mounting

7
Outside, W × H × D
We confirm with your quote
Active area
344.16 × 193.59 mm
Visible window
343 × 192 mm
VESA pattern
100 × 100 mm
Mounting
Wall-mount bracket (VESA)
Net weight
3 kg
Shipping weight
4 kg

Environment

3
Operating temperature
0 to 40°C
Storage temperature
-20 to 60°C
Humidity
Working 10-90 %RH; storage 10-90 %RH

Listed in the box

  • remote control
  • wall-mount bracket

From the maker's packing list. We confirm what ships with your quote.

Confirmed with your quote

  • Price and quantity breaks
  • Lead time from your order
  • Warranty terms, in writing
  • Anything marked "we confirm" above

Not rated for outdoor use. Need touch, a different brightness or another option? Say so in the quote.

Install

Installing a wall display.

A wall display hangs on a flat bracket fixed to the wall. Most of the work is choosing the wall fixing and planning where the power and network cables come out.

Install film for this model: 3d animation from the product cad, sample artwork. No sound; every step is written out below, and pressing a step plays from there.

  1. 01

    Mark the holes

    Hold the bracket level on the wall where the screen will hang and mark its screw holes.

  2. 02

    Drill and fit anchors

    Drill at each mark and push in wall anchors that suit your wall.

  3. 03

    Fix the bracket

    Screw the bracket to the wall through the anchors, then check it is level.

  4. 04

    Run the cable

    Bring the power cable to the bracket, and a network cable if you use one.

  5. 05

    Connect and hang

    Plug the cable into the display, then lower the display onto the bracket.

  6. 06

    Check it is seated

    Make sure the display sits flat and fully down on the bracket before you let go.

  7. 07

    Add your content

    Insert the microSD card or USB stick with your pictures and videos.

  8. 08

    Power on

    Switch on the power and the screen lights up.

The full guide, with the 3D walkthrough About 30 to 60 minutes per screen with the cable route ready. One person up to about 32 in; two people for 43 and 55 in.

Where it goes

Screens like this, at work.

Example applications of this kind of screen. These are not our customers' sites, and the screens in them may be other models.

Compare

Close relatives.

See these side by side

Quote the 15.6 in wall display.

Tell us how many, where they go and how they get power. We reply by email with the price, lead time and warranty in writing.