Wall display · series B

43 in wall display

Model IMDS-W43-B

  • Resolution1920 × 1080
  • Brightness450 nits
  • TouchNo touch
  • Operating systemAndroid 9/11 (optional)
  • Power inputWe confirm with your quote

Sold by quote. Your quote states the price, lead time and warranty in writing.

43-inch wall-mount signage display, hero dark view. 3D render with sample screen artwork.43-inch wall-mount signage display, hero light view. 3D render with sample screen artwork.
3D render from the product CAD, sample artwork on the screen.

Every side

Front, back, corners and connectors.

Rendered from this model's CAD with our sample artwork. Select a picture to see it full size.

In 3D

Turn it. Take it apart.

The model is this product's CAD, simplified for the browser. Drag to turn it, pinch or Ctrl and scroll to zoom, or use the arrow keys. Separate the parts to see how the front, the panel and the rear housing and the wall bracket go together.

Screen in the model: 940.9 × 529.3 mm. Ports, buttons and vents follow the maker's drawings; use the dimension drawing for anything you cut or fix.

Specification

What the spec sheet says.

Every value below is from this model's spec sheet or drawing. Where two of the maker's documents disagree, we show "we confirm with your quote" rather than pick one.

Resolution
1920 × 1080
Brightness
450 nits
Touch
No touch
Operating system
Android 9/11 (optional)
Power input
We confirm with your quote
Outside, W × H × D
We confirm with your quote

Display

11
Aspect ratio
16:9
Panel
TFT LCD, grade A+, WLED backlight, 16.7M colours (8-bit)
Viewing angle
178/178°
Response time
8 ms
Touch
No touch
Front glass
Tempered glass, 3 mm
Double-sided
No
Screen size
43 in
Resolution
1920 × 1080
Brightness
450 nits
Contrast
≥1200:1

Computer

5
Memory (RAM)
2 or 4 GB (optional)
Storage
16, 32 or 64 GB (optional)
Storage expansion
MicroSD card slot x1
Operating system
Android 9/11 (optional)
Processor
We confirm with your quote

Connections

6
Wi-Fi
Wi-Fi, 2.4 GHz
Bluetooth
Bluetooth 4.0
Ethernet
RJ45 x1, 10/100/1000 Mbps
Cellular
Optional 4G modem; SIM card slot x1 (needs the 4G modem)
Ports
HDMI out x1 (HDMI input only with the T972 board option), 3.5 mm headphone/audio out x1, USB x2, microSD card slot x1, SIM card slot x1 (needs optional 4G modem), RJ45 x1 (10/100/1000), DC power x1
Speakers
2 x 5 W, 8 ohm

Power

2
Power input
We confirm with your quote
Power draw
≤85 W (max)

Size and mounting

9
Mounting
Wall mount, landscape or portrait
Colour
Black, white or silver (optional)
Outside, W × H × D
We confirm with your quote
Depth without bracket
68.5 mm
Active area
940.896 × 529.254 mm
Visible window
939.2 × 527.4 mm
VESA pattern
400 × 400 mm (keyholes)
Net weight
Around 24.5 kg
Shipping weight
Around 26 kg (excluding wooden case)

Environment

2
Operating temperature
0 to +50°C
Humidity
Working 10-85 %RH; storage 10-85 %RH

Listed in the box

  • antenna
  • remote control

From the maker's packing list. We confirm what ships with your quote.

Confirmed with your quote

  • Price and quantity breaks
  • Lead time from your order
  • Warranty terms, in writing
  • Anything marked "we confirm" above

Not rated for outdoor use. Need touch, a different brightness or another option? Say so in the quote.

Dimensions

Measured, not guessed.

Third-angle views in millimetres, drawn from the product CAD. Use the numbers on the drawing for planning; check the drawing that comes with your quote before you cut anything.

Web 3D model, GLBDrawing, image

43-inch wall-mount signage display: front, side, top and rear views with dimensions in millimetres.

Install

Installing a wall display.

A wall display hangs on a flat bracket fixed to the wall. Most of the work is choosing the wall fixing and planning where the power and network cables come out.

Install film for this model: 3d animation from the product cad, sample artwork. No sound; every step is written out below, and pressing a step plays from there.

  1. 01

    Mark the holes

    Hold the bracket level on the wall where the screen will hang and mark its screw holes.

  2. 02

    Drill and fit anchors

    Drill at each mark and push in wall anchors that suit your wall.

  3. 03

    Fix the bracket

    Screw the bracket to the wall through the anchors, then check it is level.

  4. 04

    Run the cable

    Bring the power cable to the bracket, and a network cable if you use one.

  5. 05

    Add your content

    Before you hang it, insert the microSD card or USB stick with your pictures and videos.

  6. 06

    Connect and hang

    Plug the cable into the display, then lower the display onto the bracket.

  7. 07

    Check it is seated

    Make sure the display sits flat and fully down on the bracket before you let go.

  8. 08

    Power on

    Switch on the power and the screen lights up.

The full guide, with the 3D walkthrough About 30 to 60 minutes per screen with the cable route ready. One person up to about 32 in; two people for 43 and 55 in.

Where it goes

Screens like this, at work.

Example applications of this kind of screen. These are not our customers' sites, and the screens in them may be other models.

Compare

Close relatives.

See these side by side

Quote the 43 in wall display.

Tell us how many, where they go and how they get power. We reply by email with the price, lead time and warranty in writing.