Wall display · series A

32 in wall display

Model IMDS-W32-A

  • Outside, W × H × DWe confirm with your quote

Sold by quote. Your quote states the price, lead time and warranty in writing.

32-inch wall-mount signage display, hero dark view. 3D render with sample screen artwork.32-inch wall-mount signage display, hero light view. 3D render with sample screen artwork.
3D render from the product CAD, sample artwork on the screen.

Every side

Front, back, corners and connectors.

Rendered from this model's CAD with our sample artwork. Select a picture to see it full size.

In 3D

Turn it. Take it apart.

The model is this product's CAD, simplified for the browser. Drag to turn it, pinch or Ctrl and scroll to zoom, or use the arrow keys. Separate the parts to see how the front, the panel and the rear housing and the wall bracket go together.

Screen in the model: 702.4 × 403.7 mm. Ports, buttons and vents follow the maker's drawings; use the dimension drawing for anything you cut or fix.

Specification

What the spec sheet says.

This model's full specification sheet is not in yet. The values below come from its drawings; everything else is confirmed with your quote.

Outside, W × H × D
We confirm with your quote

Display

2
Screen size
32 in
Double-sided
No

Size and mounting

5
Outside, W × H × D
We confirm with your quote
Depth without bracket
54.2 mm
Visible window
698 × 391.8 mm
VESA pattern
400 × 200 mm (bracket 454.06 wide)
Mounting
Wall mount (rear bracket)

Confirmed with your quote

  • Price and quantity breaks
  • Lead time from your order
  • Warranty terms, in writing
  • Anything marked "we confirm" above

Not rated for outdoor use. Need touch, a different brightness or another option? Say so in the quote.

Install

Installing a wall display.

A wall display hangs on a flat bracket fixed to the wall. Most of the work is choosing the wall fixing and planning where the power and network cables come out.

  1. 01

    Mark the bracket

    Hold the bracket level at the planned height and mark its holes. Check with the level again after marking.

  2. 02

    Fix the bracket

    Drill for your fixings, then screw the bracket to the wall. Pull on it firmly: it should not move at all.

  3. 03

    Connect the cables

    With the display face down on a soft cloth, connect power and, if used, the network cable. Route them so they do not pinch between the display and the wall.

  4. 04

    Hang the display

    Lift the display onto the bracket, hooks over the bracket edge, and lower it until it seats. Check it is seated on every hook before you let go.

  5. 05

    Lock it

    Fit the locking screws where the bracket has them, so the display cannot be lifted off.

  6. 06

    Power on and load content

    Switch on. Insert the USB stick or microSD card, whichever your model takes (its page lists the slots), with your pictures and videos, and follow the screen to start the show.

The full guide, with the 3D walkthrough About 30 to 60 minutes per screen with the cable route ready. One person up to about 32 in; two people for 43 and 55 in.

Where it goes

Screens like this, at work.

Example applications of this kind of screen. These are not our customers' sites, and the screens in them may be other models.

Compare

Close relatives.

See these side by side

Quote the 32 in wall display.

Tell us how many, where they go and how they get power. We reply by email with the price, lead time and warranty in writing.