Wall · series A
10.1 in wall display
Specification with your quote
IMDS-W101-A
Wall display · series B
Model IMDS-W32-B
Sold by quote. Your quote states the price, lead time and warranty in writing.

Every side
Rendered from this model's CAD with our sample artwork. Select a picture to see it full size.
In 3D
The model is this product's CAD, simplified for the browser. Drag to turn it, pinch or Ctrl and scroll to zoom, or use the arrow keys. Separate the parts to see how the front, the panel and the rear housing and the wall bracket go together.
Screen in the model: 698.4 × 392.8 mm. Ports, buttons and vents follow the maker's drawings; use the dimension drawing for anything you cut or fix.

Specification
Every value below is from this model's spec sheet or drawing. Where two of the maker's documents disagree, we show "we confirm with your quote" rather than pick one.
From the maker's packing list. We confirm what ships with your quote.
Not rated for outdoor use. Need touch, a different brightness or another option? Say so in the quote.
Install
A wall display hangs on a flat bracket fixed to the wall. Most of the work is choosing the wall fixing and planning where the power and network cables come out.
Install film shown on the 43 in model of this series, which mounts the same way; take hole positions from this model's drawing and its weight from its spec sheet: 3d animation from the product cad, sample artwork. No sound; every step is written out below, and pressing a step plays from there.
01Hold the bracket level on the wall where the screen will hang and mark its screw holes.
02Drill at each mark and push in wall anchors that suit your wall.
03Screw the bracket to the wall through the anchors, then check it is level.
04Bring the power cable to the bracket, and a network cable if you use one.
05Before you hang it, insert the microSD card or USB stick with your pictures and videos.
06Plug the cable into the display, then lower the display onto the bracket.
07Make sure the display sits flat and fully down on the bracket before you let go.
08Switch on the power and the screen lights up.
The full guide, with the 3D walkthrough About 30 to 60 minutes per screen with the cable route ready. One person up to about 32 in; two people for 43 and 55 in.
Where it goes
Example applications of this kind of screen. These are not our customers' sites, and the screens in them may be other models.
Compare


Wall · series A
Specification with your quote
IMDS-W101-A


Wall · series A
1920 × 1080 · 250 nits · No touch; touch can be added
IMDS-W156-A


Wall · series B
1920 × 1080 · 300 nits · No touch
IMDS-W156-B


Wall · series C
1920 × 1080 · 250 nits · No touch
IMDS-W156-C
Tell us how many, where they go and how they get power. We reply by email with the price, lead time and warranty in writing.