Mounting height calculator

How high should the screen go on the wall?

The centre of the picture belongs at the eye height of the people who watch it. Enter the size and who is watching to get the height of the centre, the bottom edge and the top edge, then check the angle from where people sit or stand.

Mounting height chart, 16:9 screens

The height of the centre of the picture above the floor, with the bottom and top edges under it. Each size has its own page with a drawing to scale, overhead mounting distances and the accessibility limits.

SizeOn a sofa
eyes about 42 in up
At a meeting table
eyes about 48 in up
Standing
eyes about 60 in up
Overhead, 80 in clear below
people stand at least
32 in
15.7 in high
Centre 42 in
34.2 to 49.8 in
Centre 48 in
40.2 to 55.8 in
Centre 60 in
52.2 to 67.8 in
8.7 ft (2.6 m) away
40 in
19.6 in high
Centre 42 in
32.2 to 51.8 in
Centre 48 in
38.2 to 57.8 in
Centre 60 in
50.2 to 69.8 in
9.3 ft (2.8 m) away
43 in
21.1 in high
Centre 42 in
31.5 to 52.5 in
Centre 48 in
37.5 to 58.5 in
Centre 60 in
49.5 to 70.5 in
9.5 ft (2.9 m) away
50 in
24.5 in high
Centre 42 in
29.7 to 54.3 in
Centre 48 in
35.7 to 60.3 in
Centre 60 in
47.7 to 72.3 in
10 ft (3.1 m) away
55 in
27.0 in high
Centre 42 in
28.5 to 55.5 in
Centre 48 in
34.5 to 61.5 in
Centre 60 in
46.5 to 73.5 in
10 ft (3.2 m) away
60 in
29.4 in high
Centre 42 in
27.3 to 56.7 in
Centre 48 in
33.3 to 62.7 in
Centre 60 in
45.3 to 74.7 in
11 ft (3.3 m) away
65 in
31.9 in high
Centre 42 in
26.1 to 57.9 in
Centre 48 in
32.1 to 63.9 in
Centre 60 in
44.1 to 75.9 in
11 ft (3.4 m) away
70 in
34.3 in high
Centre 42 in
24.8 to 59.2 in
Centre 48 in
30.8 to 65.2 in
Centre 60 in
42.8 to 77.2 in
12 ft (3.5 m) away
75 in
36.8 in high
Centre 42 in
24.0 to 60.8 in
Centre 48 in
30.0 to 66.8 in
Centre 60 in
41.6 to 78.4 in
12 ft (3.6 m) away
77 in
37.8 in high
Centre 43 in
24.0 to 61.8 in
Centre 49 in
30.0 to 67.8 in
Centre 60 in
41.1 to 78.9 in
12 ft (3.7 m) away
83 in
40.7 in high
Centre 44 in
24.0 to 64.7 in
Centre 50 in
30.0 to 70.7 in
Centre 60 in
39.7 to 80.3 in
13 ft (3.8 m) away
85 in
41.7 in high
Centre 45 in
24.0 to 65.7 in
Centre 51 in
30.0 to 71.7 in
Centre 60 in
39.2 to 80.8 in
13 ft (3.9 m) away
86 in
42.2 in high
Centre 45 in
24.0 to 66.2 in
Centre 51 in
30.0 to 72.2 in
Centre 60 in
38.9 to 81.1 in
13 ft (3.9 m) away
98 in
48.0 in high
Centre 48 in
24.0 to 72.0 in
Centre 54 in
30.0 to 78.0 in
Centre 60 in
36.0 to 84.0 in
14 ft (4.2 m) away

Planning figures for a first mark on the wall, measured to the lit picture. The seated rows keep the bottom edge at least 24 in up for a low cabinet and 30 in up for a table top, which raises the largest sizes above eye level. Measure the eye height of your own seats where you can, and check the bracket position on the drawing of the exact model.

How we work it out

The centre goes at eye height: about 42 inches for a sofa, 48 inches for a desk or meeting chair and 60 inches for an adult standing. The bottom edge is half the picture height below the centre and the top edge half above. If that puts the bottom edge behind a cabinet or a table, the screen moves up until it clears.

For a screen above eye level, a common comfort rule keeps the centre no more than 15 degrees above the eye line. That is about 3.2 inches of extra height for every foot of distance, so from 10 feet the centre can sit 32 inches above the eyes.

In a public space

In the United States, the 2010 ADA Standards limit anything on a wall with its leading edge more than 27 and not more than 80 inches above the floor to 4 inches of protrusion into a circulation path, and call for 80 inches of headroom. Touch targets belong between 15 and 48 inches from the floor.

A screen recessed into the wall meets the protrusion limit at any height; the flush mount guide shows how. To pick the size first, use the viewing distance calculator for signs or the meeting room calculator for a room where people sit, and the screen size calculator for width and height.

Questions

How high should a TV or display be mounted?

Put the centre of the picture at the eye height of the people who watch it: about 42 inches from the floor for people on a sofa, about 48 inches for people at a desk or meeting table, and about 60 inches for people standing. Then check that the bottom edge clears whatever sits under it.

Is above a fireplace or a door too high?

It depends on how far back people sit or stand. A common comfort rule keeps the centre of the picture no more than 15 degrees above the eye line. For someone seated 9 feet away with eyes at 42 inches, that tops out at a centre about 71 inches from the floor. Higher than that, tilt the screen down or expect people to look up.

How far can a wall-mounted screen stick out in a public corridor?

In the United States, the 2010 ADA Standards limit objects on a wall to 4 inches of protrusion into a circulation path when their leading edge is more than 27 and not more than 80 inches above the floor. That counts the screen and its bracket together. A screen recessed into the wall, or one with its bottom edge at 80 inches or higher, avoids the limit. Ask your local code official about your building.

How high should a touch screen be?

Anything people must press has to be within reach. The 2010 ADA Standards put an unobstructed reach between 15 and 48 inches above the floor, so keep buttons and other touch targets in that band, even when the picture itself extends higher.