Mounting height

How high should a 77-inch screen be mounted?

Put the centre of the picture at the eye height of the people who watch it. For a 77-inch screen that means a centre 42.9 in (109 cm) from the floor for people on a sofa, 48.9 in (124 cm) at a meeting table, and 60.0 in (152 cm) for people standing.

Mounting height for a 77-inch screen: centre 43 in from the floor for seated viewers and 60 in for standing viewers, drawn to scale
Drawn to scale. The solid shape is the screen at seated height and the dashed outline is the same screen at standing height.
Mounting heights for a 77-inch 16:9 screen, measured from the floor
Who is watchingCentreBottom edgeTop edge
Seated on a sofa or lounge chair
eyes about 42 in up
42.9 in (109 cm)
raised to clear a low cabinet
24.0 in (61 cm)61.8 in (157 cm)
Seated at a desk or meeting table
eyes about 48 in up
48.9 in (124 cm)
raised to clear the table top
30.0 in (76 cm)67.8 in (172 cm)
Standing
eyes about 60 in up
60.0 in (152 cm)41.1 in (104 cm)78.9 in (200 cm)
Standing, screen in portrait
eyes about 60 in up
60.0 in (152 cm)26.4 in (67 cm)93.6 in (238 cm)

Heights are to the lit picture of a 16:9 screen, 67.1 x 37.8 in (170.5 x 95.9 cm) at this size; all 77-inch dimensions. The frame adds a little above and below. The bracket holes are not always at the centre of the cabinet, so measure from the holes to the bottom edge on your model before you drill. For other eye heights, use the mounting height calculator.

How high can a 77-inch screen go?

A screen above a counter, a door or a walkway sits above eye level on purpose. A common comfort rule keeps the centre of the picture no more than 15 degrees above the eye line. The farther back people stand, the higher the screen can go.

People standHighest comfortable centreBottom edge thenTop edge thenClear to walk under?
6 ft (1.8 m) away79.3 in (201 cm)60.4 in (153 cm)98.2 in (249 cm)No
8 ft (2.4 m) away85.7 in (218 cm)66.8 in (170 cm)104.6 in (266 cm)No
10 ft (3.0 m) away92.2 in (234 cm)73.3 in (186 cm)111.0 in (282 cm)No
12 ft (3.7 m) away98.6 in (250 cm)79.7 in (202 cm)117.5 in (298 cm)No
15 ft (4.6 m) away108.2 in (275 cm)89.4 in (227 cm)127.1 in (323 cm)Yes, 80 in or more
20 ft (6.1 m) away124.3 in (316 cm)105.4 in (268 cm)143.2 in (364 cm)Yes, 80 in or more
25 ft (7.6 m) away140.4 in (357 cm)121.5 in (309 cm)159.3 in (405 cm)Yes, 80 in or more
30 ft (9.1 m) away156.5 in (397 cm)137.6 in (349 cm)175.3 in (445 cm)Yes, 80 in or more

For standing viewers with eyes 60 in from the floor. To hang a 77-inch screen with 80 in of headroom under it, the centre is 98.9 in (251 cm) up, and that meets the 15 degree rule from about 12 ft (3.7 m) away. Closer than that, tilt the screen down. A sign people only glance at can sit higher than one they read for a minute.

In a corridor or a public space

At standing eye level, the bottom edge of a 77-inch screen is 41.1 in (104 cm) from the floor. In the United States, the 2010 ADA Standards limit anything on a wall with its leading edge more than 27 and not more than 80 inches above the floor to 4 inches of protrusion into a circulation path. The screen and its bracket count together.

Three ways to meet it: choose a screen and bracket that stay within 4 inches, recess the screen into the wall so the face sits flush, or raise it until the bottom edge is 80 inches up. Our flush mount guide covers the recessed route. Your local code official has the final word.

If it is a touch screen

People have to reach what they press. The same standards put an unobstructed reach between 15 and 48 inches above the floor.

The picture of a 77-inch landscape screen is 37.8 inches high, taller than that 33 inch band, so only about 87 percent of its height can be in reach at once. Mount it for viewing, and lay out the buttons and other touch targets in the part of the picture between 15 and 48 inches from the floor.

Questions

How high should a 77-inch TV be mounted?

Put the centre of the picture at the eye height of the people watching. For people on a sofa that is about 42 inches from the floor, which puts the bottom edge of a 77-inch screen at 24.0 in (61 cm) and the top at 61.8 in (157 cm), after raising it to a 43-inch centre so the bottom edge clears a low cabinet. For people standing, a 60-inch centre puts the bottom edge at 41.1 in (104 cm) and the top at 78.9 in (200 cm).

How far from the floor should the bottom of a 77-inch TV be?

About 24 inches for sofa viewing, 30 inches in a meeting room and 41 inches where people stand. The picture of a 77-inch 16:9 screen is 37.8 inches high, so the bottom edge sits half of that below the centre. The frame adds a little.

Can a 77-inch screen hang above head height?

Yes, if people stand far enough back. With the bottom edge 80 inches up, the centre of a 77-inch screen is 98.9 in (251 cm) from the floor. Standing viewers look up at more than 15 degrees until they are about 12 ft (3.7 m) away, so plan for readers at that distance or beyond, or tilt the screen down.

← 75 inchMounting height calculator83 inch →