Dual-screen table player · series D

7 in dual-screen table player

Model IMDS-TPD7-D

  • Resolution800 × 1280 (each screen, portrait)
  • Brightness600 nits
  • TouchCapacitive, both screens
  • Operating systemAndroid 11
  • Power input12V / 2A DC adapter

Sold by quote. Your quote states the price, lead time and warranty in writing.

7-inch dual-screen table player, hero dark view. 3D render with sample screen artwork.7-inch dual-screen table player, hero light view. 3D render with sample screen artwork.
3D render from the product CAD, sample artwork on the screen.

Every side

Front, back, corners and connectors.

Rendered from this model's CAD with our sample artwork. Select a picture to see it full size.

A full turn, rendered from the product CAD. No sound.

In 3D

Turn it. Take it apart.

The model is this product's CAD, simplified for the browser. Drag to turn it, pinch or Ctrl and scroll to zoom, or use the arrow keys. Separate the parts to see how the front, the panel and the rear housing go together.

Screen in the model: 94.2 × 150.8 mm. Ports, buttons and vents follow the maker's drawings; use the dimension drawing for anything you cut or fix.

Specification

What the spec sheet says.

This model's full specification sheet is not in yet. The values below come from its drawings; everything else is confirmed with your quote.

Resolution
800 × 1280 (each screen, portrait)
Brightness
600 nits
Touch
Capacitive, both screens
Operating system
Android 11
Power input
12V / 2A DC adapter

Display

7
Screen size
7 in
Panel
IPS LCD
Resolution
800 × 1280 (each screen, portrait)
Aspect ratio
10:16 portrait
Brightness
600 nits
Touch
Capacitive, both screens
Double-sided
Yes

Computer

5
Operating system
Android 11
Processor
RK3568
CPU
Quad-core 64-bit Cortex-A55, max 2.0 GHz
Memory (RAM)
4 GB
Storage
32 GB

Connections

6
Wi-Fi
Wi-Fi, 2.4 and 5 GHz
Bluetooth
Dual-mode Bluetooth 5.0
Ports
DC input 12V / 2A, 2x USB-A charging outputs, 5V / 2.0A (one per side), built-in 3-in-1 phone cable (Micro USB + Type C + Lightning) on one side, second built-in phone cable on the other side, battery level indicator
Speakers
1x 8 ohm / 1 W
Camera
Optional
Sensors
We confirm with your quote

Power

3
Power input
12V / 2A DC adapter
Battery
23200 mAh Li-ion, built in (not detachable); up to 21 hours screen display
Wireless charging
None built in; optional clip-on 2 x 5 W Qi wireless charger accessory

Size and mounting

4
Outside, W × H × D
We confirm with your quote
Enclosure
Fire-resistant ABS
Colour
Black / Wood Grain
Mounting
Tabletop; optional anti-theft lock plate

Listed in the box

  • DC 12V / 2A adapter
  • Built-in 3-in-1 phone cable (iPhone / Micro / Type C) and 1 Type C phone cable
  • Manual

From the maker's packing list. We confirm what ships with your quote.

Confirmed with your quote

  • Price and quantity breaks
  • Lead time from your order
  • Warranty terms, in writing
  • Anything marked "we confirm" above

Not rated for outdoor use. Need touch, a different brightness or another option? Say so in the quote.

Install

Setting up a table player.

Table players sit on a table, counter or reception desk. There is nothing to mount: charge it or plug it in, load your content and place it.

Install film for this model: 3d animation from the product cad, sample artwork. No sound; every step is written out below, and pressing a step plays from there.

  1. 01

    Set it by an outlet

    Set the player on a flat surface near a power outlet to charge it.

  2. 02

    Charge the battery

    Connect the power cable and charge the battery before first use.

  3. 03

    Place it on the table

    Unplug the cable and set the player where people will see it; it runs on its battery.

  4. 04

    Power on

    Switch it on and the screen lights up.

  5. 05

    Add your content

    Load your pictures and videos over Wi-Fi, and they play on both screens.

  6. 06

    Touch to interact

    Tap the screen: the capacitive touch panel responds to your fingers.

The full guide, with the 3D walkthrough About 10 minutes, plus the first full charge on the battery model. One person.

Where it goes

Screens like this, at work.

Example applications of this kind of screen. These are not our customers' sites, and the screens in them may be other models.

Compare

Close relatives.

See these side by side

Quote the 7 in dual-screen table player.

Tell us how many, where they go and how they get power. We reply by email with the price, lead time and warranty in writing.