Dual-screen A-frame table player · series D

7 in dual-screen a-frame table player

Model IMDS-TPA7-D

  • Brightness600 nits
  • TouchCapacitive multi-point (40 channels), both screens
  • Operating systemAndroid 11
  • Power input12V / 2A DC adapter

Sold by quote. Your quote states the price, lead time and warranty in writing.

7-inch dual-screen A-frame table player, hero dark view. 3D render with sample screen artwork.7-inch dual-screen A-frame table player, hero light view. 3D render with sample screen artwork.
3D render from the product CAD, sample artwork on the screen.

Every side

Front, back, corners and connectors.

Rendered from this model's CAD with our sample artwork. Select a picture to see it full size.

A full turn, rendered from the product CAD. No sound.

In 3D

Turn it. Take it apart.

The model is this product's CAD, simplified for the browser. Drag to turn it, pinch or Ctrl and scroll to zoom, or use the arrow keys. Separate the parts to see how the front, the panel and the rear housing go together.

Screen in the model: 94.2 × 150 mm. Ports, buttons and vents follow the maker's drawings; use the dimension drawing for anything you cut or fix.

Specification

What the spec sheet says.

Every value below is from this model's spec sheet or drawing. Where two of the maker's documents disagree, we show "we confirm with your quote" rather than pick one.

Brightness
600 nits
Touch
Capacitive multi-point (40 channels), both screens
Operating system
Android 11
Power input
12V / 2A DC adapter

Display

7
Screen size
7 in
Panel
IPS (MIPI)
Resolution
We confirm with your quote
Aspect ratio
Portrait
Brightness
600 nits
Touch
Capacitive multi-point (40 channels), both screens
Double-sided
Yes

Computer

7
Operating system
Android 11
Processor
RK3568 (22 nm)
CPU
Quad-core 64-bit Cortex-A55, up to 2.0 GHz
Graphics
ARM G52 2EE
Memory (RAM)
4 GB
Storage
32 GB
Storage expansion
MicroSD card up to 64 GB

Connections

6
Wi-Fi
Wi-Fi, 2.4 and 5 GHz
Bluetooth
Dual-mode Bluetooth 5.0
Cellular
4G; 100 Mbps down / 50 Mbps up; optional SIM holder
Ports
1x Micro USB 2.0 OTG (USB stick, app install), microSD card slot, 4G SIM holder (optional), DC input 12V / 2A, 1x USB charging output (2A), built-in 3-in-1 phone cable (Lightning / Micro USB / USB-C)
Speakers
1x 8 ohm / 1 W
Sensors
Motion sensor: detects people, screen auto-on (built in per price list)

Power

3
Power input
12V / 2A DC adapter
Power draw
We confirm with your quote
Battery
We confirm with your quote

Size and mounting

5
Outside, W × H × D
We confirm with your quote
Net weight
1.2 kg
Enclosure
Fire-resistant ABS
Colour
We confirm with your quote
Mounting
Tabletop A-frame; optional anti-theft lock plate; optional charging dock

Listed in the box

  • DC 12V / 2A adapter
  • Built-in 3-in-1 phone cable (iPhone / Micro / Type C)
  • Manual
  • Order option: phone cable on one side as standard

From the maker's packing list. We confirm what ships with your quote.

Confirmed with your quote

  • Price and quantity breaks
  • Lead time from your order
  • Warranty terms, in writing
  • Anything marked "we confirm" above

Not rated for outdoor use. Need touch, a different brightness or another option? Say so in the quote.

Install

Setting up a table player.

Table players sit on a table, counter or reception desk. There is nothing to mount: charge it or plug it in, load your content and place it.

Install film for this model: 3d animation from the product cad, sample artwork. No sound; every step is written out below, and pressing a step plays from there.

  1. 01

    Set it by an outlet

    Set the player on a flat surface near a power outlet to charge it.

  2. 02

    Charge the battery

    Connect the power cable and charge the battery before first use.

  3. 03

    Place it on the table

    Unplug the cable and set the player where people will see it; it runs on its battery.

  4. 04

    Power on

    Switch it on and the screen lights up.

  5. 05

    Add your content

    Upload your pictures and videos over Wi-Fi with the content software, and they play on both screens.

  6. 06

    Touch to interact

    Tap the screen: the capacitive touch panel responds to your fingers.

The full guide, with the 3D walkthrough About 10 minutes, plus the first full charge on the battery model. One person.

Where it goes

Screens like this, at work.

Example applications of this kind of screen. These are not our customers' sites, and the screens in them may be other models.

Compare

Close relatives.

See these side by side

Quote the 7 in dual-screen a-frame table player.

Tell us how many, where they go and how they get power. We reply by email with the price, lead time and warranty in writing.