

Wall · series A
10.1 in wall display
Specification with your quote
IMDS-W101-A
Table player · series D
Model IMDS-TP7-D
Sold by quote. Your quote states the price, lead time and warranty in writing.

Every side
Rendered from this model's CAD with our sample artwork. Select a picture to see it full size.
A full turn, rendered from the product CAD. No sound.
In 3D
The model is this product's CAD, simplified for the browser. Drag to turn it, pinch or Ctrl and scroll to zoom, or use the arrow keys. Separate the parts to see how the front, the panel and the rear housing go together.
Screen in the model: 89.9 × 153.4 mm. Ports, buttons and vents follow the maker's drawings; use the dimension drawing for anything you cut or fix.

Specification
Every value below is from this model's spec sheet or drawing. Where two of the maker's documents disagree, we show "we confirm with your quote" rather than pick one.
From the maker's packing list. We confirm what ships with your quote.
Not rated for outdoor use. Need touch, a different brightness or another option? Say so in the quote.
Install
Table players sit on a table, counter or reception desk. There is nothing to mount: charge it or plug it in, load your content and place it.
Install film for this model: 3d animation from the product cad, sample artwork. No sound; every step is written out below, and pressing a step plays from there.
01Set the player on a flat surface near a power outlet to charge it.
02Connect the power cable and charge the battery before first use.
03Unplug the cable and set the player where people will see it; it runs on its battery.
04Switch it on and the screen lights up.
05Upload your pictures and videos over Wi-Fi with the content software, and they play on the screen.
06Tap the screen: the capacitive touch panel responds to your fingers.
The full guide, with the 3D walkthrough About 10 minutes, plus the first full charge on the battery model. One person.
Where it goes
Example applications of this kind of screen. These are not our customers' sites, and the screens in them may be other models.
Compare


Wall · series A
Specification with your quote
IMDS-W101-A


Wall · series B
1280 × 800 · 350 nits · No touch
IMDS-W101-B


Desk and counter · series E
1920 × 1080 · 300 nits · 10-point capacitive
IMDS-DK14-E


Wall · series A
1920 × 1080 · 250 nits · No touch; touch can be added
IMDS-W156-A
Tell us how many, where they go and how they get power. We reply by email with the price, lead time and warranty in writing.