Size comparison

27 vs 32 inch: how much bigger?

A 32-inch screen is 4.4 inches wider and 2.5 inches taller than a 27-inch screen (11.1 cm and 6.2 cm), and it shows 40 percent more picture. Both are the usual 16:9 shape, measured on the lit picture.

27-inch vs 32-inch screen size comparison, drawn to scale on one centre
Drawn to scale on one centre. The dark shape is the 27-inch screen and the lighter shape behind it is the 32-inch screen.
27-inch and 32-inch 16:9 screen dimensions compared
16:9 picture27 inch32 inchDifference
Width23.5 in
59.8 cm
27.9 in
70.8 cm
4.4 in
11.1 cm
Height13.2 in
33.6 cm
15.7 in
39.8 cm
2.5 in
6.2 cm
Diagonal27 in
68.6 cm
32 in
81.3 cm
19% longer
Picture area2.2 sq ft
0.201 m²
3.0 sq ft
0.282 m²
40% more

Worked from the diagonal and the 16:9 shape, so these describe the lit picture only. In portrait, swap each width and height. The outside of a cabinet is larger by the width of its frame, so use the drawing of the exact model for a recess or a tight wall.

How far away does each one read?

The larger screen fits bigger letters for the same words, so the same message reads from farther away. Each distance is the farthest point where that much text still fits at a letter height people can read, in landscape.

On the screen27 inch, read from up to32 inch, read from up to
One short line
A sign or a room name
123 ft (37.4 m)
capitals 4.1 in tall
145 ft (44.3 m)
capitals 4.8 in tall
Three short lines
One message on a slide
78 ft (23.7 m)
capitals 2.6 in tall
92 ft (28.1 m)
capitals 3.1 in tall
A list of eight lines
A menu, a schedule or a directory
29 ft (8.9 m)
capitals 1.0 in tall
35 ft (10.5 m)
capitals 1.2 in tall
Pictures and video
Little or no small text
Works well to 11 ft (3.4 m)
18 ft (5.4 m) is the limit
Works well to 13 ft (4.0 m)
21 ft (6.4 m) is the limit

We plan on 1 inch of capital letter height for every 30 feet of distance, assuming 20/40 vision, and a line takes 1.7 times the capital height. For pictures the rule of thumb is 10 times the picture height, with 16 times as the limit. To start from your own distance, use the viewing distance calculator.

Pixel size at the same resolution

If both screens have the same resolution, the larger one has larger pixels, so it needs a little more distance before the picture looks smooth.

Resolution27 inch pixel pitch32 inch pixel pitchPixels blend from
Full HD, 1920 x 10800.311 mm0.369 mm3.5 ft (1.1 m) and 4.2 ft (1.3 m)
4K, 3840 x 21600.156 mm0.184 mm1.8 ft (0.5 m) and 2.1 ft (0.6 m)

Pixels blend where one pixel takes up about one arcminute of your vision. Whether a given model is Full HD or 4K is on its own spec sheet.

Questions

How much bigger is a 32-inch screen than a 27-inch screen?

A 32-inch 16:9 screen is 4.4 inches (11.1 cm) wider and 2.5 inches (6.2 cm) taller than a 27-inch one, and it has 40 percent more picture area. The diagonal grows by 19 percent, but area grows with the square of the diagonal.

Will a 32-inch screen fit where a 27-inch screen fits?

Only if the space has 4.4 inches (11.1 cm) more width and 2.5 inches (6.2 cm) more height to spare, before the frame. The picture of a 32-inch screen is 27.9 x 15.7 inches; check the outline on the drawing of the exact model before you commit.

From how far away does the extra size matter?

For pictures and video our rule of thumb is 10 times the picture height: about 11 ft (3.4 m) for the 27-inch and 13 ft (4.0 m) for the 32-inch. If people stand farther back than the first distance, the larger screen is the safer choice.

More comparisons

24 vs 27 inch32 vs 40 inch32 vs 43 inch

← 27 inch dimensionsScreen size calculator32 inch dimensions →