Screen dimensions

How big is a 27-inch screen?

A 27-inch screen in the usual 16:9 shape has a lit picture 23.5 inches wide and 13.2 inches high (59.8 x 33.6 cm). The 27 inches (68.6 cm) is the diagonal, corner to corner. The frame around the picture adds to the outside size.

27-inch 16:9 screen dimensions: 23.5 x 13.2 in (59.8 x 33.6 cm), drawn to scale
Drawn to scale. The solid shape is the screen in landscape and the dashed outline is the same screen turned to portrait.
27-inch 16:9 screen dimensions
27 in, 16:9InchesCentimetresMillimetres
Width, landscape23.5 in59.8 cm598 mm
Height, landscape13.2 in33.6 cm336 mm
Width, portrait13.2 in33.6 cm336 mm
Height, portrait23.5 in59.8 cm598 mm
Diagonal27 in68.6 cm686 mm
Picture area312 sq in2.2 sq ft (0.201 m²)

These are worked from the diagonal and the 16:9 shape, so they describe the lit picture only. A real panel can differ by a few millimetres, and the outside of the cabinet is larger by the width of its frame. Use the drawing of the exact model for a cut-out, a recess or a tight alcove.

Displays we make at 27 inches

The picture size above is the same for all of them. The outline is the outside of each cabinet, from its drawing.

ModelResolutionOutline, W x H x D
27-inch slim wall display, series D1920 x 1080623.5 × 361.5 × 23.02 mm

How far away can people read a 27-inch screen?

It depends on how much text you put on it. Fewer lines means bigger letters, and bigger letters read from farther away. Each distance below is the farthest point where that much text still fits at a letter height people can read.

On the screenTallest capital letters that fitLandscape, read from up toPortrait, read from up to
One short line
A sign or a room name
4.1 in (104 mm)123 ft (37.4 m)
82 ft (24.9 m) for fast reading
69 ft (21.0 m)
46 ft (14.0 m) for fast reading
Three short lines
One message on a slide
2.6 in (66 mm)78 ft (23.7 m)
52 ft (15.8 m) for fast reading
46 ft (14.0 m)
31 ft (9.3 m) for fast reading
A list of eight lines
A menu, a schedule or a directory
1.0 in (25 mm)29 ft (8.9 m)
19 ft (5.9 m) for fast reading
31 ft (9.3 m)
20 ft (6.2 m) for fast reading
Pictures and video
Little or no small text
Not applicableWorks well to 11 ft (3.4 m)
18 ft (5.4 m) is the limit
Works well to 20 ft (6.0 m)
31 ft (9.6 m) is the limit

We plan on 1 inch of capital letter height for every 30 feet of distance, the road-sign planning figure reported by Federal Highway Administration research, which assumes 20/40 vision. 20 feet per inch is the safer figure for fast reading. A line takes 1.7 times the capital height. For pictures and video our rule of thumb is 10 times the picture height, with 16 times as the limit. Thin fonts, weak contrast and glare all shorten these distances. To start from the distance instead, use the viewing distance calculator.

A 27-inch screen next to the sizes around it

SizePicture, W x HDifference in widthDifference in heightPicture area
24 in20.9 x 11.8 in (53.1 x 29.9 cm)2.6 in (6.6 cm) narrower1.5 in (3.7 cm) shorterThe 27 is 27% larger
27 in23.5 x 13.2 in (59.8 x 33.6 cm)This sizeThis size2.2 sq ft
32 in27.9 x 15.7 in (70.8 x 39.8 cm)4.4 in (11.1 cm) wider2.5 in (6.2 cm) tallerThe 32 is 40% larger

Area grows with the square of the diagonal, so a small step in inches is a bigger step in picture. See every size in one table.

Drawn to scale, side by side:24 vs 27 inch27 vs 32 inch

Pixel size on a 27-inch screen

The same resolution spread over a bigger picture makes bigger pixels. From the distance in the last column, a person with normal eyesight no longer sees separate pixels.

ResolutionPixel pitchPixels per inchPixels blend from
HD, 1366 x 7680.438 mm584.9 ft (1.5 m)
Full HD, 1920 x 10800.311 mm823.5 ft (1.1 m)
4K, 3840 x 21600.156 mm1631.8 ft (0.5 m)

Pixels blend where one pixel takes up about one arcminute of your vision. Whether a given model is HD, Full HD or 4K is on its own spec sheet.

Video walls made of 27-inch screens

LayoutScreensPicture, W x HIn feetOverall diagonal
2 across247.1 x 13.2 in (119.5 x 33.6 cm)3.9 x 1.1 ft49 in
2 high223.5 x 26.5 in (59.8 x 67.2 cm)2.0 x 2.2 ft35 in
2 x 2447.1 x 26.5 in (119.5 x 67.2 cm)3.9 x 2.2 ft54 in
3 across370.6 x 13.2 in (179.3 x 33.6 cm)5.9 x 1.1 ft72 in
3 x 3970.6 x 39.7 in (179.3 x 100.9 cm)5.9 x 3.3 ft81 in
4 x 41694.1 x 52.9 in (239.1 x 134.5 cm)7.8 x 4.4 ft108 in

Landscape screens, picture only. Every frame between two screens adds a gap, so the finished wall is a little larger than this. Add the frame width from the drawing for each join.

Other shapes with a 27-inch diagonal

The diagonal alone does not fix the width. A squarer screen with the same diagonal is narrower and taller, and it has more picture area.

ShapeWhere you find itWidth x heightArea against 16:9
16:9Most signage displays, TVs and monitors23.5 x 13.2 in (59.8 x 33.6 cm)100%
16:10Laptops, tablets and many small panels22.9 x 14.3 in (58.2 x 36.3 cm)105%
4:3Older monitors and some kiosks21.6 x 16.2 in (54.9 x 41.1 cm)112%
5:4Older 17 and 19 inch monitors21.1 x 16.9 in (53.6 x 42.8 cm)114%
21:9Ultrawide monitors24.8 x 10.6 in (63.0 x 27.0 cm)85%
32:9Stretched bar displays and super-ultrawide monitors26.0 x 7.3 in (66.0 x 18.6 cm)61%

Questions

How many cm is 27 inches?

27 inches is 68.6 cm (686 mm). On a screen that length is the diagonal, so a 27-inch 16:9 picture is 59.8 cm wide and 33.6 cm high.

How wide is a 27-inch screen?

The lit picture of a 27-inch 16:9 screen is 23.5 inches wide (59.8 cm) and 13.2 inches high (33.6 cm). The frame around it adds to both, so read the outline on the drawing of the exact model before you cut or build anything.

How tall is a 27-inch screen in portrait?

Turned upright, the same picture is 13.2 inches wide (33.6 cm) and 23.5 inches tall (59.8 cm), plus the frame. Check that the model is built to run in portrait before you turn it.

Is 27 inches the width of the screen?

No. 27 inches (68.6 cm) is the diagonal of the lit picture, measured corner to corner. A 16:9 screen is about 87 percent of its diagonal wide and 49 percent of its diagonal high.

← 24 inchScreen size calculator32 inch →