

Wall · series A
43 in wall display
Specification with your quote
IMDS-W43-A
Slim wall monitor · series D
Model IMDS-WM43-D
Sold by quote. Your quote states the price, lead time and warranty in writing.

Every side
Rendered from this model's CAD with our sample artwork. Select a picture to see it full size.
A full turn, rendered from the product CAD. No sound.
In 3D
The model is this product's CAD, simplified for the browser. Drag to turn it, pinch or Ctrl and scroll to zoom, or use the arrow keys. Separate the parts to see how the front, the panel and the rear housing go together.

Specification
Every value below is from this model's spec sheet or drawing. Where two of the maker's documents disagree, we show "we confirm with your quote" rather than pick one.
From the maker's packing list. We confirm what ships with your quote.
Not rated for outdoor use. Need touch, a different brightness or another option? Say so in the quote.
Install
A wall display hangs on a flat bracket fixed to the wall. Most of the work is choosing the wall fixing and planning where the power cable, and a network cable on models that take one, come out.
Install film for this model: 3d animation from the product cad, sample artwork. No sound; every step is written out below, and pressing a step plays from there.
01Hold the wall plate level on the wall where the screen will hang and mark its screw holes.
02Drill at each mark and push in wall anchors that suit your wall.
03Screw the plate to the wall through the anchors, then check it is level.
04The power cord is built into the monitor: check the outlet is within its reach.
05Before you hang it, insert a TF card with your pictures and videos: the monitor plays them from the card.
06Plug the monitor's power cord into the outlet, then lower the monitor onto the plate.
07Make sure the display sits flat and fully down on the plate before you let go.
08Switch on the power and the screen lights up.
The full guide, with the 3D walkthrough About 30 to 60 minutes per screen with the cable route ready. One person up to about 32 in; two people for 43 in and larger.
Where it goes
Example applications of this kind of screen. These are not our customers' sites, and the screens in them may be other models.
Compare


Wall · series A
Specification with your quote
IMDS-W43-A


Wall · series B
1920 × 1080 or 3840 × 2160 · 450 nits · No touch
IMDS-W43-B


Wall · series D
1920 × 1080
IMDS-WS43-D


Wall · series D
1920 × 1080
IMDS-WF43-D
Tell us how many, where they go and how they get power. We reply by email with the price, lead time and warranty in writing.