Wall display · series D

21.5 in wall display

Model IMDS-W215-D

  • Resolution1920 × 1080
  • Brightness500 nits
  • Operating systemAndroid 11.0
  • Power inputAC 100-240 V 50/60 Hz
  • Outside, W × H × D504.06 × 295.79 × 28 mm

Sold by quote. Your quote states the price, lead time and warranty in writing.

21.5-inch wall-mount signage display, hero dark view. 3D render with sample screen artwork.21.5-inch wall-mount signage display, hero light view. 3D render with sample screen artwork.
3D render from the product CAD, sample artwork on the screen.

Every side

Front, back, corners and connectors.

Rendered from this model's CAD with our sample artwork. Select a picture to see it full size.

A full turn, rendered from the product CAD. No sound.

In 3D

Turn it. Take it apart.

The model is this product's CAD, simplified for the browser. Drag to turn it, pinch or Ctrl and scroll to zoom, or use the arrow keys. Separate the parts to see how the front, the panel and the rear housing go together.

Active area from the spec sheet: 475.06 × 266.79 mm. Ports, buttons and vents follow the maker's drawings; use the dimension drawing for anything you cut or fix.

Specification

What the spec sheet says.

Every value below is from this model's spec sheet or drawing. Where two of the maker's documents disagree, we show "we confirm with your quote" rather than pick one.

Resolution
1920 × 1080
Brightness
500 nits
Operating system
Android 11.0
Power input
AC 100-240 V 50/60 Hz
Outside, W × H × D
504.06 × 295.79 × 28 mm

Display

8
Screen size
21.5 in
Panel
IPS, normally black
Resolution
1920 × 1080
Aspect ratio
16:9
Brightness
500 nits
Contrast
1200:1
Viewing angle
178/178/178/178° (L/R/U/D)
Double-sided
No

Computer

5
Processor
We confirm with your quote
Memory (RAM)
We confirm with your quote
Storage
We confirm with your quote
Storage expansion
MicroSD card x1, up to 64 GB
Operating system
Android 11.0

Connections

5
Wi-Fi
Wi-Fi, 2.4 GHz
Bluetooth
Bluetooth 4.0
Ethernet
10/100 Mbps RJ45 x1
Ports
We confirm with your quote
Speakers
We confirm with your quote

Power

2
Power input
AC 100-240 V 50/60 Hz
Power draw
≤35 W

Size and mounting

8
Active area
475.06 × 266.79 mm
Outside, W × H × D
504.06 × 295.79 × 28 mm
Depth
28 mm
VESA pattern
150 × 150 mm (compatible bracket optional)
Mounting
Flush wall mount on the included ultra-thin wall plate, 2 mm from the wall; landscape or portrait; optional recessed (embedded) install; optional mobile stand with rotation and height adjustment
Net weight
4.2 kg (excludes the 0.8 kg wall plate)
Shipping weight
6.5 kg
Enclosure
Aluminium structure

Environment

3
Operating temperature
0 to 50°C
Storage temperature
-10 to +60°C
Humidity
≤80% RH

Listed in the box

  • User manual (electronic or paper)
  • Antenna rod
  • Power cord
  • Ultra-thin wall plate (0.8 kg, shipped by default)
  • Hanger (0.75 kg) is weighed separately

From the maker's packing list. We confirm what ships with your quote.

Confirmed with your quote

  • Price and quantity breaks
  • Lead time from your order
  • Warranty terms, in writing
  • Anything marked "we confirm" above

Not rated for outdoor use. Need touch, a different brightness or another option? Say so in the quote.

Dimensions

Measured, not guessed.

Third-angle views in millimetres, drawn from the product CAD. Use the numbers on the drawing for planning; check the drawing that comes with your quote before you cut anything.

Web 3D model, GLBDrawing, image

21.5-inch wall-mount signage display: front, side, top and rear views with dimensions in millimetres.

Install

Installing a wall display.

A wall display hangs on a flat bracket fixed to the wall. Most of the work is choosing the wall fixing and planning where the power cable, and a network cable on models that take one, come out.

Install film for this model: 3d animation from the product cad, sample artwork. No sound; every step is written out below, and pressing a step plays from there.

  1. 01

    Mark the holes

    Hold the wall plate level on the wall where the screen will hang and mark its screw holes.

  2. 02

    Drill and fit anchors

    Drill at each mark and push in wall anchors that suit your wall.

  3. 03

    Fix the plate

    Screw the plate to the wall through the anchors, then check it is level.

  4. 04

    Run the cable

    Check the outlet is within reach of the power cord, and run a network cable if you use one.

  5. 05

    Connect and hang

    Route the power cord out through the slot in the left edge, plug it into the outlet, then lower the display onto the plate.

  6. 06

    Check it is seated

    Make sure the display sits flat and fully down on the plate before you let go.

  7. 07

    Add your content

    Insert the USB stick with your pictures and videos into the USB port on the left edge.

  8. 08

    Power on

    Switch on the power and the screen lights up.

The full guide, with the 3D walkthrough About 30 to 60 minutes per screen with the cable route ready. One person up to about 32 in; two people for 43 in and larger.

Where it goes

Screens like this, at work.

Example applications of this kind of screen. These are not our customers' sites, and the screens in them may be other models.

Compare

Close relatives.

See these side by side

Quote the 21.5 in wall display.

Tell us how many, where they go and how they get power. We reply by email with the price, lead time and warranty in writing.