Single-sided hanging window display · series D

55 in single-sided hanging window display

Model IMDS-WHS55-D

  • Brightness700 or 3000 nits (two builds: SM55A-1 ≥700, SM55A-2 ≥3000)
  • Operating systemAndroid 11
  • Power inputAC 100-240 V 50/60 Hz, 3 m power cord
  • Outside, W × H × D711.6 × 1300.8 × 59 mm

Sold by quote. Your quote states the price, lead time and warranty in writing.

55-inch single-sided hanging window display, hero dark view. 3D render with sample screen artwork.55-inch single-sided hanging window display, hero light view. 3D render with sample screen artwork.
3D render from the product CAD, sample artwork on the screen.

Every side

Front, back, corners and connectors.

Rendered from this model's CAD with our sample artwork. Select a picture to see it full size.

A full turn, rendered from the product CAD. No sound.

In 3D

Turn it. See both sides.

The model is this product's CAD, simplified for the browser. Drag to turn it, pinch or Ctrl and scroll to zoom, or use the arrow keys.

Active area from the spec sheet: 680.4 × 1209.6 mm (portrait W x H). Use the dimension drawing supplied with your quote for anything you cut or fix.

Specification

What the spec sheet says.

Every value below is from this model's spec sheet or drawing. Where two of the maker's documents disagree, we show "we confirm with your quote" rather than pick one.

Brightness
700 or 3000 nits (two builds: SM55A-1 ≥700, SM55A-2 ≥3000)
Operating system
Android 11
Power input
AC 100-240 V 50/60 Hz, 3 m power cord
Outside, W × H × D
711.6 × 1300.8 × 59 mm

Display

8
Screen size
55 in
Panel
IPS, normally black
Resolution
We confirm with your quote
Aspect ratio
16:9 (portrait orientation)
Brightness
700 or 3000 nits (two builds: SM55A-1 ≥700, SM55A-2 ≥3000)
Contrast
1200:1
Viewing angle
178/178/178/178° (L/R/U/D)
Double-sided
No

Computer

5
Processor
RK3568
CPU
Quad-core Cortex-A55, 1.8 GHz
Memory (RAM)
We confirm with your quote
Storage
We confirm with your quote
Operating system
Android 11

Connections

6
Wi-Fi
Wi-Fi, 2.4 GHz
Bluetooth
Bluetooth 5.0
Ethernet
1x RJ45, 10/100 Mbps
Ports
USB x2 (1 host, 1 OTG), one at the top and one at the bottom, RJ45 x1, AC power cord 3 m
Speakers
8 ohm 5 W custom speaker
Sensors
Ambient light sensor: automatic brightness, plus manual brightness by knob

Power

2
Power input
AC 100-240 V 50/60 Hz, 3 m power cord
Power draw
≤200 or ≤350 W

Size and mounting

8
Active area
680.4 × 1209.6 mm (portrait W x H)
Outside, W × H × D
711.6 × 1300.8 × 59 mm
Depth
59 mm
Mounting
Single-sided ceiling hanging on two telescopic rods; drop 0.5 to 2 m, adjustable in 10 cm steps; other lengths to order
Net weight
27 kg
Shipping weight
39 kg
Enclosure
Aluminium structure
Colour
Black

Environment

3
Operating temperature
0 to 50°C
Storage temperature
-10 to +60°C
Humidity
≤80% RH operating

Listed in the box

  • User manual (electronic or paper)
  • Antenna rod
  • Power cord 3 m
  • Hanging bracket

From the maker's packing list. We confirm what ships with your quote.

Confirmed with your quote

  • Price and quantity breaks
  • Lead time from your order
  • Warranty terms, in writing
  • Anything marked "we confirm" above

Not rated for outdoor use. Need touch, a different brightness or another option? Say so in the quote.

Dimensions

Dimensions for planning.

Third-angle views in millimetres, drawn from the product CAD. Use the numbers on the drawing for planning; check the drawing that comes with your quote before you cut anything.

Web 3D model, GLBDrawing, image

55-inch single-sided hanging window display: front, side, top and rear views with dimensions in millimetres.

Install

Hanging a window display.

A hanging display comes down from the ceiling on two rods, usually just inside a shop window. A double-sided model shows the street one face and the shop the other; a single-sided model turns its screen to whichever side you choose and shows a closed back on the other. All the work is overhead: the ceiling fixings carry the whole weight, and the cables come down beside the rods to the top of the display.

Install film for this model: 3d animation from the product cad, sample artwork. No sound; every step is written out below, and pressing a step plays from there.

  1. 01

    Mark the ceiling

    Hold the ceiling rail in place, square to the window, and mark its fixing holes.

  2. 02

    Fix the ceiling rail and rods

    Fix the rail into the structure, test it, then fit both rods at the same length.

  3. 03

    Connect the cables

    Before lifting, run the cables down beside a rod to the top bar, connect them and insert your content.

  4. 04

    Hang it

    Lift the display onto both rods and check each connection is locked before letting go.

  5. 05

    Level and power on

    Check it hangs level, then switch on: the content plays on the screen face.

The full guide, with the 3D walkthrough About 1 to 2 hours, most of it at the ceiling. Two people on stable platforms: one holds the display while the other connects it to the rods.

Where it goes

Screens like this, at work.

Example applications of this kind of screen. These are not our customers' sites, and the screens in them may be other models.

Compare

Close relatives.

See these side by side

Quote the 55 in single-sided hanging window display.

Tell us how many, where they go and how they get power. We reply by email with the price, lead time and warranty in writing.