Size comparison

75 vs 85 inch: how much bigger?

A 85-inch screen is 8.7 inches wider and 4.9 inches taller than a 75-inch screen (22.1 cm and 12.5 cm), and it shows 28 percent more picture. Both are the usual 16:9 shape, measured on the lit picture.

75-inch vs 85-inch screen size comparison, drawn to scale on one centre
Drawn to scale on one centre. The dark shape is the 75-inch screen and the lighter shape behind it is the 85-inch screen.
75-inch and 85-inch 16:9 screen dimensions compared
16:9 picture75 inch85 inchDifference
Width65.4 in
166.0 cm
74.1 in
188.2 cm
8.7 in
22.1 cm
Height36.8 in
93.4 cm
41.7 in
105.8 cm
4.9 in
12.5 cm
Diagonal75 in
190.5 cm
85 in
215.9 cm
13% longer
Picture area16.7 sq ft
1.55 m²
21.4 sq ft
1.99 m²
28% more

Worked from the diagonal and the 16:9 shape, so these describe the lit picture only. In portrait, swap each width and height. The outside of a cabinet is larger by the width of its frame, so use the drawing of the exact model for a recess or a tight wall.

How far away does each one read?

The larger screen fits bigger letters for the same words, so the same message reads from farther away. Each distance is the farthest point where that much text still fits at a letter height people can read, in landscape.

On the screen75 inch, read from up to85 inch, read from up to
One short line
A sign or a room name
340 ft (103.8 m)
capitals 11.3 in tall
386 ft (117.6 m)
capitals 12.9 in tall
Three short lines
One message on a slide
216 ft (65.9 m)
capitals 7.2 in tall
245 ft (74.7 m)
capitals 8.2 in tall
A list of eight lines
A menu, a schedule or a directory
81 ft (24.7 m)
capitals 2.7 in tall
92 ft (28.0 m)
capitals 3.1 in tall
Pictures and video
Little or no small text
Works well to 31 ft (9.3 m)
49 ft (14.9 m) is the limit
Works well to 35 ft (10.6 m)
56 ft (16.9 m) is the limit

We plan on 1 inch of capital letter height for every 30 feet of distance, assuming 20/40 vision, and a line takes 1.7 times the capital height. For pictures the rule of thumb is 10 times the picture height, with 16 times as the limit. To start from your own distance, use the viewing distance calculator.

Pixel size at the same resolution

If both screens have the same resolution, the larger one has larger pixels, so it needs a little more distance before the picture looks smooth.

Resolution75 inch pixel pitch85 inch pixel pitchPixels blend from
Full HD, 1920 x 10800.865 mm0.980 mm9.8 ft (3.0 m) and 11 ft (3.4 m)
4K, 3840 x 21600.432 mm0.490 mm4.9 ft (1.5 m) and 5.5 ft (1.7 m)

Pixels blend where one pixel takes up about one arcminute of your vision. Whether a given model is Full HD or 4K is on its own spec sheet.

Questions

How much bigger is a 85-inch screen than a 75-inch screen?

A 85-inch 16:9 screen is 8.7 inches (22.1 cm) wider and 4.9 inches (12.5 cm) taller than a 75-inch one, and it has 28 percent more picture area. The diagonal grows by 13 percent, but area grows with the square of the diagonal.

Will a 85-inch screen fit where a 75-inch screen fits?

Only if the space has 8.7 inches (22.1 cm) more width and 4.9 inches (12.5 cm) more height to spare, before the frame. The picture of a 85-inch screen is 74.1 x 41.7 inches; check the outline on the drawing of the exact model before you commit.

From how far away does the extra size matter?

For pictures and video our rule of thumb is 10 times the picture height: about 31 ft (9.3 m) for the 75-inch and 35 ft (10.6 m) for the 85-inch. If people stand farther back than the first distance, the larger screen is the safer choice.

More comparisons

55 vs 75 inch65 vs 75 inch65 vs 85 inch70 vs 75 inch75 vs 77 inch75 vs 86 inch83 vs 85 inch85 vs 98 inch

← 75 inch dimensionsScreen size calculator85 inch dimensions →