Screen dimensions

How big is a 50-inch screen?

A 50-inch screen in the usual 16:9 shape has a lit picture 43.6 inches wide and 24.5 inches high (110.7 x 62.3 cm). The 50 inches (127.0 cm) is the diagonal, corner to corner. The frame around the picture adds to the outside size.

50-inch 16:9 screen dimensions: 43.6 x 24.5 in (110.7 x 62.3 cm), drawn to scale
Drawn to scale. The solid shape is the screen in landscape and the dashed outline is the same screen turned to portrait.
50-inch 16:9 screen dimensions
50 in, 16:9InchesCentimetresMillimetres
Width, landscape43.6 in110.7 cm1107 mm
Height, landscape24.5 in62.3 cm623 mm
Width, portrait24.5 in62.3 cm623 mm
Height, portrait43.6 in110.7 cm1107 mm
Diagonal50 in127.0 cm1270 mm
Picture area1,068 sq in7.4 sq ft (0.69 m²)

These are worked from the diagonal and the 16:9 shape, so they describe the lit picture only. A real panel can differ by a few millimetres, and the outside of the cabinet is larger by the width of its frame. Use the drawing of the exact model for a cut-out, a recess or a tight alcove. For the height on the wall, see how high to mount a 50-inch screen.

How far away can people read a 50-inch screen?

It depends on how much text you put on it. Fewer lines means bigger letters, and bigger letters read from farther away. Each distance below is the farthest point where that much text still fits at a letter height people can read.

On the screenTallest capital letters that fitLandscape, read from up toPortrait, read from up to
One short line
A sign or a room name
7.6 in (192 mm)227 ft (69.2 m)
151 ft (46.1 m) for fast reading
128 ft (38.9 m)
85 ft (25.9 m) for fast reading
Three short lines
One message on a slide
4.8 in (122 mm)144 ft (44.0 m)
96 ft (29.3 m) for fast reading
85 ft (25.9 m)
57 ft (17.3 m) for fast reading
A list of eight lines
A menu, a schedule or a directory
1.8 in (46 mm)54 ft (16.5 m)
36 ft (11.0 m) for fast reading
57 ft (17.3 m)
38 ft (11.5 m) for fast reading
Pictures and video
Little or no small text
Not applicableWorks well to 20 ft (6.2 m)
33 ft (10.0 m) is the limit
Works well to 36 ft (11.1 m)
58 ft (17.7 m) is the limit

We plan on 1 inch of capital letter height for every 30 feet of distance, the road-sign planning figure reported by Federal Highway Administration research, which assumes 20/40 vision. 20 feet per inch is the safer figure for fast reading. A line takes 1.7 times the capital height. For pictures and video our rule of thumb is 10 times the picture height, with 16 times as the limit. Thin fonts, weak contrast and glare all shorten these distances. To start from the distance instead, use the viewing distance calculator.

A 50-inch screen next to the sizes around it

SizePicture, W x HDifference in widthDifference in heightPicture area
49 in42.7 x 24.0 in (108.5 x 61.0 cm)0.9 in (2.2 cm) narrower0.5 in (1.2 cm) shorterThe 50 is 4% larger
50 in43.6 x 24.5 in (110.7 x 62.3 cm)This sizeThis size7.4 sq ft
55 in47.9 x 27.0 in (121.8 x 68.5 cm)4.4 in (11.1 cm) wider2.5 in (6.2 cm) tallerThe 55 is 21% larger

Area grows with the square of the diagonal, so a small step in inches is a bigger step in picture. See every size in one table.

Drawn to scale, side by side:43 vs 50 inch50 vs 55 inch50 vs 65 inch

Pixel size on a 50-inch screen

The same resolution spread over a bigger picture makes bigger pixels. From the distance in the last column, a person with normal eyesight no longer sees separate pixels.

ResolutionPixel pitchPixels per inchPixels blend from
Full HD, 1920 x 10800.577 mm446.5 ft (2.0 m)
4K, 3840 x 21600.288 mm883.3 ft (1.0 m)

Pixels blend where one pixel takes up about one arcminute of your vision. Whether a given model is HD, Full HD or 4K is on its own spec sheet.

Video walls made of 50-inch screens

LayoutScreensPicture, W x HIn feetOverall diagonal
2 across287.2 x 24.5 in (221.4 x 62.3 cm)7.3 x 2.0 ft91 in
2 high243.6 x 49.0 in (110.7 x 124.5 cm)3.6 x 4.1 ft66 in
2 x 2487.2 x 49.0 in (221.4 x 124.5 cm)7.3 x 4.1 ft100 in
3 across3130.7 x 24.5 in (332.1 x 62.3 cm)10.9 x 2.0 ft133 in
3 x 39130.7 x 73.5 in (332.1 x 186.8 cm)10.9 x 6.1 ft150 in
4 x 416174.3 x 98.1 in (442.8 x 249.1 cm)14.5 x 8.2 ft200 in

Landscape screens, picture only. Every frame between two screens adds a gap, so the finished wall is a little larger than this. Add the frame width from the drawing for each join.

Other shapes with a 50-inch diagonal

The diagonal alone does not fix the width. A squarer screen with the same diagonal is narrower and taller, and it has more picture area.

ShapeWhere you find itWidth x heightArea against 16:9
16:9Most signage displays, TVs and monitors43.6 x 24.5 in (110.7 x 62.3 cm)100%
16:10Laptops, tablets and many small panels42.4 x 26.5 in (107.7 x 67.3 cm)105%
4:3Older monitors and some kiosks40.0 x 30.0 in (101.6 x 76.2 cm)112%
5:4Older 17 and 19 inch monitors39.0 x 31.2 in (99.2 x 79.3 cm)114%
21:9Ultrawide monitors46.0 x 19.7 in (116.7 x 50.0 cm)85%
32:9Stretched bar displays and super-ultrawide monitors48.1 x 13.5 in (122.3 x 34.4 cm)61%

Questions

How many cm is 50 inches?

50 inches is 127.0 cm (1270 mm). On a screen that length is the diagonal, so a 50-inch 16:9 picture is 110.7 cm wide and 62.3 cm high.

How wide is a 50-inch screen?

The lit picture of a 50-inch 16:9 screen is 43.6 inches wide (110.7 cm) and 24.5 inches high (62.3 cm). The frame around it adds to both, so read the outline on the drawing of the exact model before you cut or build anything.

How tall is a 50-inch screen in portrait?

Turned upright, the same picture is 24.5 inches wide (62.3 cm) and 43.6 inches tall (110.7 cm), plus the frame. Check that the model is built to run in portrait before you turn it.

Is 50 inches the width of the screen?

No. 50 inches (127.0 cm) is the diagonal of the lit picture, measured corner to corner. A 16:9 screen is about 87 percent of its diagonal wide and 49 percent of its diagonal high.

← 49 inchScreen size calculator55 inch →