Screen dimensions

How big is a 23.8-inch screen?

A 23.8-inch screen in the usual 16:9 shape has a lit picture 20.7 inches wide and 11.7 inches high (52.7 x 29.6 cm). The 23.8 inches (60.5 cm) is the diagonal, corner to corner. The frame around the picture adds to the outside size.

23.8-inch 16:9 screen dimensions: 20.7 x 11.7 in (52.7 x 29.6 cm), drawn to scale
Drawn to scale. The solid shape is the screen in landscape and the dashed outline is the same screen turned to portrait.
23.8-inch 16:9 screen dimensions
23.8 in, 16:9InchesCentimetresMillimetres
Width, landscape20.7 in52.7 cm527 mm
Height, landscape11.7 in29.6 cm296 mm
Width, portrait11.7 in29.6 cm296 mm
Height, portrait20.7 in52.7 cm527 mm
Diagonal23.8 in60.5 cm605 mm
Picture area242 sq in1.7 sq ft (0.156 m²)

These are worked from the diagonal and the 16:9 shape, so they describe the lit picture only. A real panel can differ by a few millimetres, and the outside of the cabinet is larger by the width of its frame. Use the drawing of the exact model for a cut-out, a recess or a tight alcove.

How far away can people read a 23.8-inch screen?

It depends on how much text you put on it. Fewer lines means bigger letters, and bigger letters read from farther away. Each distance below is the farthest point where that much text still fits at a letter height people can read.

On the screenTallest capital letters that fitLandscape, read from up toPortrait, read from up to
One short line
A sign or a room name
3.6 in (91 mm)108 ft (32.9 m)
72 ft (22.0 m) for fast reading
61 ft (18.5 m)
41 ft (12.3 m) for fast reading
Three short lines
One message on a slide
2.3 in (58 mm)69 ft (20.9 m)
46 ft (13.9 m) for fast reading
41 ft (12.3 m)
27 ft (8.2 m) for fast reading
A list of eight lines
A menu, a schedule or a directory
0.9 in (22 mm)26 ft (7.8 m)
17 ft (5.2 m) for fast reading
27 ft (8.2 m)
18 ft (5.5 m) for fast reading
Pictures and video
Little or no small text
Not applicableWorks well to 9.7 ft (3.0 m)
16 ft (4.7 m) is the limit
Works well to 17 ft (5.3 m)
28 ft (8.4 m) is the limit

We plan on 1 inch of capital letter height for every 30 feet of distance, the road-sign planning figure reported by Federal Highway Administration research, which assumes 20/40 vision. 20 feet per inch is the safer figure for fast reading. A line takes 1.7 times the capital height. For pictures and video our rule of thumb is 10 times the picture height, with 16 times as the limit. Thin fonts, weak contrast and glare all shorten these distances. To start from the distance instead, use the viewing distance calculator.

A 23.8-inch screen next to the sizes around it

SizePicture, W x HDifference in widthDifference in heightPicture area
22 in19.2 x 10.8 in (48.7 x 27.4 cm)1.6 in (4.0 cm) narrower0.9 in (2.2 cm) shorterThe 23.8 is 17% larger
23.8 in20.7 x 11.7 in (52.7 x 29.6 cm)This sizeThis size1.7 sq ft
24 in20.9 x 11.8 in (53.1 x 29.9 cm)0.2 in (0.4 cm) wider0.1 in (0.2 cm) tallerThe 24 is 2% larger

Area grows with the square of the diagonal, so a small step in inches is a bigger step in picture. See every size in one table.

Pixel size on a 23.8-inch screen

The same resolution spread over a bigger picture makes bigger pixels. From the distance in the last column, a person with normal eyesight no longer sees separate pixels.

ResolutionPixel pitchPixels per inchPixels blend from
HD, 1366 x 7680.386 mm664.4 ft (1.3 m)
Full HD, 1920 x 10800.274 mm933.1 ft (0.9 m)
4K, 3840 x 21600.137 mm1851.5 ft (0.5 m)

Pixels blend where one pixel takes up about one arcminute of your vision. Whether a given model is HD, Full HD or 4K is on its own spec sheet.

Video walls made of 23.8-inch screens

LayoutScreensPicture, W x HIn feetOverall diagonal
2 across241.5 x 11.7 in (105.4 x 29.6 cm)3.5 x 1.0 ft43 in
2 high220.7 x 23.3 in (52.7 x 59.3 cm)1.7 x 1.9 ft31 in
2 x 2441.5 x 23.3 in (105.4 x 59.3 cm)3.5 x 1.9 ft48 in
3 across362.2 x 11.7 in (158.1 x 29.6 cm)5.2 x 1.0 ft63 in
3 x 3962.2 x 35.0 in (158.1 x 88.9 cm)5.2 x 2.9 ft71 in
4 x 41683.0 x 46.7 in (210.8 x 118.5 cm)6.9 x 3.9 ft95 in

Landscape screens, picture only. Every frame between two screens adds a gap, so the finished wall is a little larger than this. Add the frame width from the drawing for each join.

Other shapes with a 23.8-inch diagonal

The diagonal alone does not fix the width. A squarer screen with the same diagonal is narrower and taller, and it has more picture area.

ShapeWhere you find itWidth x heightArea against 16:9
16:9Most signage displays, TVs and monitors20.7 x 11.7 in (52.7 x 29.6 cm)100%
16:10Laptops, tablets and many small panels20.2 x 12.6 in (51.3 x 32.0 cm)105%
4:3Older monitors and some kiosks19.0 x 14.3 in (48.4 x 36.3 cm)112%
5:4Older 17 and 19 inch monitors18.6 x 14.9 in (47.2 x 37.8 cm)114%
21:9Ultrawide monitors21.9 x 9.4 in (55.6 x 23.8 cm)85%
32:9Stretched bar displays and super-ultrawide monitors22.9 x 6.4 in (58.2 x 16.4 cm)61%

Questions

How many cm is 23.8 inches?

23.8 inches is 60.5 cm (605 mm). On a screen that length is the diagonal, so a 23.8-inch 16:9 picture is 52.7 cm wide and 29.6 cm high.

How wide is a 23.8-inch screen?

The lit picture of a 23.8-inch 16:9 screen is 20.7 inches wide (52.7 cm) and 11.7 inches high (29.6 cm). The frame around it adds to both, so read the outline on the drawing of the exact model before you cut or build anything.

How tall is a 23.8-inch screen in portrait?

Turned upright, the same picture is 11.7 inches wide (29.6 cm) and 20.7 inches tall (52.7 cm), plus the frame. Check that the model is built to run in portrait before you turn it.

Is 23.8 inches the width of the screen?

No. 23.8 inches (60.5 cm) is the diagonal of the lit picture, measured corner to corner. A 16:9 screen is about 87 percent of its diagonal wide and 49 percent of its diagonal high.

← 22 inchScreen size calculator24 inch →