Touch wall display · series D

43 in touch wall display

Model IMDS-WT43-D

  • Resolution1920 × 1080
  • TouchCapacitive, finger or dedicated capacitive pen
  • Operating systemAndroid 11.0
  • Power inputAC 100-240 V 50/60 Hz, power cord
  • Outside, W × H × D981.18 × 569.42 × 28 mm

Sold by quote. Your quote states the price, lead time and warranty in writing.

43-inch touch wall-mount signage display, hero dark view. 3D render with sample screen artwork.43-inch touch wall-mount signage display, hero light view. 3D render with sample screen artwork.
3D render from the product CAD, sample artwork on the screen.

Every side

Front, back, corners and connectors.

Rendered from this model's CAD with our sample artwork. Select a picture to see it full size.

A full turn, rendered from the product CAD. No sound.

In 3D

Turn it. Take it apart.

The model is this product's CAD, simplified for the browser. Drag to turn it, pinch or Ctrl and scroll to zoom, or use the arrow keys. Separate the parts to see how the front, the panel and the rear housing go together.

Specification

What the spec sheet says.

Every value below is from this model's spec sheet or drawing. Where two of the maker's documents disagree, we show "we confirm with your quote" rather than pick one.

Resolution
1920 × 1080
Touch
Capacitive, finger or dedicated capacitive pen
Operating system
Android 11.0
Power input
AC 100-240 V 50/60 Hz, power cord
Outside, W × H × D
981.18 × 569.42 × 28 mm

Display

16
Screen size
43 in
Panel
IPS, normally black
Resolution
1920 × 1080
Aspect ratio
16:9
Brightness
We confirm with your quote
Contrast
1200:1
Viewing angle
178/178/178/178° (L/R/U/D)
Front glass
We confirm with your quote
Glass hardness
We confirm with your quote
Light transmission
We confirm with your quote
Touch
Capacitive, finger or dedicated capacitive pen
Double-sided
No
Touch points
10
Touch response
8 ms
Touch accuracy
<2 mm deviation
Touch life
>80 million single touches

Computer

5
Processor
RK3566
Memory (RAM)
2G/4G/8G optional
Storage
We confirm with your quote
Storage expansion
MicroSD card x1, up to 64 GB
Operating system
Android 11.0

Connections

5
Wi-Fi
Wi-Fi, 2.4 GHz
Bluetooth
Bluetooth 4.0
Ethernet
10/100 Mbps RJ45 x1
Ports
HDMI output x1, microSD card x1, USB x2 (1 host, 1 OTG), RJ45 x1, 3.5 mm stereo earphone out x1, AC power cord
Speakers
We confirm with your quote

Power

2
Power input
AC 100-240 V 50/60 Hz, power cord
Power draw
We confirm with your quote

Size and mounting

9
Active area
We confirm with your quote
Outside, W × H × D
981.18 × 569.42 × 28 mm
Depth
28 mm
VESA pattern
400 × 400 mm, 4 x M8
Mounting
Wall mount in landscape or portrait with the supplied wall-hanging plate and small installation accessories; optional embedded installation; optional mobile stand
Net weight
We confirm with your quote
Shipping weight
We confirm with your quote
Enclosure
Aluminium frame, iron back plate
Colour
We confirm with your quote

Environment

3
Operating temperature
0 to 50°C
Storage temperature
-10 to +60°C
Humidity
≤80% RH

Listed in the box

  • User manual (electronic or paper)
  • Antenna
  • Power cord
  • Wall plate, shipped by default; net weight excludes it
  • Hanger is weighed separately

From the maker's packing list. We confirm what ships with your quote.

Confirmed with your quote

  • Price and quantity breaks
  • Lead time from your order
  • Warranty terms, in writing
  • Anything marked "we confirm" above

Not rated for outdoor use. Need touch, a different brightness or another option? Say so in the quote.

Dimensions

Measured, not guessed.

Third-angle views in millimetres, drawn from the product CAD. Use the numbers on the drawing for planning; check the drawing that comes with your quote before you cut anything.

Web 3D model, GLBDrawing, image

43-inch touch wall-mount signage display: front, side, top and rear views with dimensions in millimetres.

Install

Installing a wall display.

A wall display hangs on a flat bracket fixed to the wall. Most of the work is choosing the wall fixing and planning where the power cable, and a network cable on models that take one, come out.

Install film for this model: 3d animation from the product cad, sample artwork. No sound; every step is written out below, and pressing a step plays from there.

  1. 01

    Mark the holes

    Hold the wall plate level on the wall where the screen will hang and mark its screw holes.

  2. 02

    Drill and fit anchors

    Drill at each mark and push in wall anchors that suit your wall.

  3. 03

    Fix the plate

    Screw the plate to the wall through the anchors, then check it is level.

  4. 04

    Run the cable

    Check the outlet is within reach of the power cord, and run a network cable if you use one.

  5. 05

    Connect and hang

    Route the power cord out through the slot in the left edge, plug it into the outlet, then lower the display onto the plate.

  6. 06

    Check it is seated

    Make sure the display sits flat and fully down on the plate before you let go.

  7. 07

    Add your content

    Insert the USB stick with your pictures and videos into the USB port on the left edge.

  8. 08

    Power on

    Switch on the power and the screen lights up.

  9. 09

    Touch to interact

    Tap the screen: the capacitive touch panel responds to your fingers.

The full guide, with the 3D walkthrough About 30 to 60 minutes per screen with the cable route ready. One person up to about 32 in; two people for 43 and 55 in.

Where it goes

Screens like this, at work.

Example applications of this kind of screen. These are not our customers' sites, and the screens in them may be other models.

Compare

Close relatives.

See these side by side

Quote the 43 in touch wall display.

Tell us how many, where they go and how they get power. We reply by email with the price, lead time and warranty in writing.