Split the endpoint at the first slash after the scheme: 192.168.0.110 is the remote server and Bender.OPC.Server.FTC470XET.DA.1 is the server name. Then prove the setup with one live item read, because a working web page exercises only the HTTP path.
Split the endpoint at the first slash after the scheme. In OPCDA://192.168.0.110/Bender.OPC.Server.FTC470XET.DA.1/, the address 192.168.0.110 is the computer that runs the server, and it goes in the remote server field. Bender.OPC.Server.FTC470XET.DA.1 is the server's DCOM ProgID, and it goes in the server name field. A classic OPC DA client asks for the two values separately because it uses them in two steps: it reaches the host first, then DCOM launches the server registered under that ProgID on the host. Treat the module's web page as a network test only. The page travels over HTTP; OPC DA travels over DCOM and RPC on a separate path, so the acceptance test for your configuration is one live item read whose value changes when the process changes. Browsing can come back empty with both fields correct, so treat a hand-entered ProgID as the normal setup.
Where each portion of the URL goes
Classic OPC DA URLs follow one documented shape, the opcda://[Hostname]/[ProgID] form published by the OPC Foundation. Three parts, two slashes:
- The scheme before
://, hereOPCDA, selects classic DA. It is never entered in either field. - The host between
://and the next/identifies the computer. An IP address or a Windows computer name works. - The ProgID after the host slash is the name the server software registers under Windows on that computer.
OpcEnumor a registry read on the host lists the exact string; copy it from there when in doubt.
| Portion of the endpoint | Client field | Value here |
|---|---|---|
OPCDA, before :// |
none, the scheme | selects classic DA |
between :// and the first / |
Remote Server | 192.168.0.110 |
between the first / and the trailing / |
ServerName | Bender.OPC.Server.FTC470XET.DA.1 |
Drop the trailing slash when you enter the ProgID. It closes the URL and belongs to neither value. Clients label the fields differently: some say Host or Node for the remote server, some say ProgID for the server name, and the mapping holds either way. If the client you are configuring is a dedicated panel, HMI panel as OPC client: can it read tags without a PLC covers what a panel client asks of the server it connects to.
What each symptom points to
- The web page loads but the OPC connection times out. The page rides HTTP on one port. OPC DA rides DCOM and RPC: TCP 135 reaches the RPC endpoint mapper on the host, and the data connection then lands on a dynamic port, 49152 to 65535 by default on current Windows. OPC DA has no single port to forward, so a firewall that passes the page can still block the client. Serving tags to a browser over HTTP is a separate route again; reading PLC tag values from an HMI panel web server covers that route.
- A standalone test client connects but your client refuses. Re-split the endpoint and compare the two fields first. Then compare the Windows account each client runs under, because DCOM checks the account of the process asking for the server.
- The browse list comes back empty. Browsing asks the host's
OpcEnumservice and DCOM to list registered servers before any connection exists, a path that can fail while a direct ProgID connection still works. Enter the ProgID by hand and test. - The connection opens but items read zero or fail. Activation is done and item access is the blocker. Take an item identifier that read in the test client and enter it character for character.
All four symptoms assume OPC DA is the right route for the job. If that choice is still open, writing a Modbus client or using an OPC server for a small HMI compares the two routes.
Checks to run first
- From the client PC, open the module's web page at
192.168.0.110. If it will not load, the fault is the network path, the subnet, or an address conflict, and no OPC setting will fix it. - On the same PC, under the same Windows account, run the standalone OPC test client the module supplier recommended. Connect with host
192.168.0.110and ProgIDBender.OPC.Server.FTC470XET.DA.1, then read one item whose value you can watch move. - Write down the exact item identifier and the endpoint string the test client reports. The endpoint is what you split into the two fields, and the item is the acceptance test for your own client.
Worked example: split OPCDA://192.168.0.110/Bender.OPC.Server.FTC470XET.DA.1/
Inputs:
- Endpoint as the standalone test client reports it:
OPCDA://192.168.0.110/Bender.OPC.Server.FTC470XET.DA.1/ - Device address on the plant LAN:
192.168.0.110 - Format rule:
opcda://[Hostname]/[ProgID], the documented classic DA shape
Rule in words: cut the string at ://, then cut again at the first / after that. What sits between the two cuts is the host. What runs from that cut to the trailing slash is the ProgID.
Arithmetic, one cut at a time:
- Before
://:OPCDA, 5 characters. Scheme, selects classic DA, entered nowhere. - Between
://and the first/:192.168.0.110, 13 characters, matching the device address that answers on the LAN. This is the Remote Server. - Between the first
/and the trailing/:Bender.OPC.Server.FTC470XET.DA.1, 32 characters, one dotted name. This is the ServerName.
Cross-check: 5 + 3 for :// + 13 + 1 for the host slash + 32 + 1 for the trailing slash = 55 characters, the length of the endpoint as reported.
Result:
- Remote Server:
192.168.0.110 - ServerName:
Bender.OPC.Server.FTC470XET.DA.1
Decision: one host segment plus one ProgID segment is the clean case, so enter the two values, connect directly by ProgID, and call the job done when a live item reads and its value tracks the process. If your endpoint carries extra segments after the ProgID, the two-field split above stops applying: read the exact ProgID from the host with OpcEnum or the registry there, and ask the server vendor what their extra path adds.
After the fields are set
| What you see | What it means | Next move |
|---|---|---|
| The client refuses to activate the server | A wrong value in one field, the server missing from the host's registration, or DCOM launch blocked | Compare both fields against the test client on the same PC, then check launch permissions for your client's account |
| The server activates, browse stays empty or items fail | Activation works; discovery and item access run on their own paths | Enter the item identifier that read in the test client, character for character |
| An item reads and its value tracks the process | Host, ProgID and data path all work | Build out the remaining tags; fix browsing later only if operators need it for setup |
Keep the test client open beside your client while you work through the rows; the comparison between the two is the diagnostic.
The decision
Recommendation: Enter the host from the first segment and the ProgID from the second segment of the endpoint in their two fields, exactly as the table above shows, and connect directly by ProgID. Judge success by one live item read whose value changes with the process, made on the same PC and Windows account where the standalone test client already works. Change DCOM or firewall settings only after the test client connects on that PC and your client still refuses, then compare the two clients' accounts and launch permissions, and take the exact endpoint, the error text and both versions to the software vendor's support channel if they match.
Questions
What happens if you paste the whole endpoint into the server name field?
The client then asks the host for a server registered under the full string, slashes included, and no server registers that way, so the lookup fails or the field rejects the entry. Split the endpoint instead: 192.168.0.110 as the remote server and Bender.OPC.Server.FTC470XET.DA.1 as the server name. A few clients are built around a single URL field instead; those take the endpoint whole, exactly as the test client reported it.
Why does the browse list stay empty even after the connection works?
Discovery and data use separate paths. The browse walks OPCEnum and DCOM before any connection exists, so a blocked route there leaves the list empty while your connected client reads values normally. Leave browsing alone unless operators pick servers from it during setup, and repair it in the host's DCOM and firewall configuration, never by changing the two connection fields.
The test client reads values and your client still refuses: what then?
Compare four things in order: the host and ProgID as entered, the item identifier, the Windows account each client runs under, and the DCOM launch and access permissions for that account on the host. If all four match and yours still refuses, stop changing fields and send the software vendor's support channel the exact endpoint, the error text and both client versions.
Planning information, not legal or engineering advice. Rules differ by place: check codes and permits with your local authority and your licensed trades.