Send a remote HMI panel backup by email for USB restore

7 min read · Published November 10, 2026

You can email a panel backup to a remote site and have it restored from a USB stick. Send the project-only file when the field panel's firmware matches the version the project was saved under; when the firmware is unknown or different, send the full package with the OS and firmware included, copy the folder structure to the stick unflattened, and have the technician back up the running panel first.

Yes. A backup made on one HMI panel can travel by email and be restored from a USB stick at the far end, so one program change can reach several sites without a drive shipped to each of them. Two conditions decide whether it works. A project-only file restores onto a target running the same firmware as the project, so the field technician reads the version before you pick the payload. And whatever you send has to reach the stick with its folder structure intact, because the restore looks for the files where the transfer wrote them. Have the technician back up the running panel first, and the whole change stays reversible.

Pick the package by the firmware on the target panel

There are two payloads, and they are not interchangeable.

A project-only backup keeps the file small, which is what makes email practical. Its restore expects a panel running the firmware version the project was saved under. So the first number in this job is the firmware version on the field panel: have the technician read it on the panel's system screen and read it back to you. Reading an HMI panel firmware version for field maintenance shows where that number sits. Compare it against the revision your project was saved under before anything is transferred, the check described in checking the HMI firmware revision before a project transfer.

When the versions differ, the panel's operating system has to be brought up to the version the engineering software expects. A larger package does that in one pass: selecting system and project on the panel backup, or generating the software's own transfer package, produces a folder carrying the OS, the firmware and the project together.

One distinction matters here: a project that opens cleanly on your bench and a panel that can restore it are two separate checks. The software check happens at your desk. The firmware check happens at the panel.

What the field panel shows What to send Why
Firmware read back, equal to the project's version Project-only package, the project file startupStorage.eas inside its folder Smallest file, attaches to an email
Firmware different from the project's version System-and-project backup, or the software's full transfer package Carries the OS and firmware; one restore updates the panel
Firmware unknown, or the panel has no program The software's full transfer package No dependency on anyone reading a version at the site

What you need

  • The engineering PC with the project and the panel software installed.
  • The firmware version read from the field panel, in hand before you choose the payload.
  • A USB stick with more room than the package. One HMI vendor's documentation names an industrial-grade stick as the storage medium and sizes a full backup for its larger panels at up to 20 GB, so a 32 GB industrial stick covers that worst case. A project-only package is far smaller; any stick on hand that exceeds the measured file will do.
  • A way past the email size cap. Most mail services cut a single message off near 20 to 25 MB. A small package attaches to the email; a full package travels as a link to a shared folder.
  • About 15 minutes of technician time at the panel for the backup, the copy and the restore.

Generate the package on the bench PC

  1. Open the project and confirm the firmware version it was saved under. Write the number down; a project-only restore has to match it at every target.
  2. Start Project Transfer in the panel software and choose External Memory Device as the destination. Your hard drive works; the point is that the software builds the folder, not you.
  3. Let the software write the package. For a project-only transfer the project file itself is startupStorage.eas; a full package adds the OS and firmware files around it.
  4. Inspect the result in the file manager before anything leaves the bench: the total folder size and a complete tree. Zip the folder, and tell the technician to extract it on the site PC before copying, because a package rebuilt by hand from loose attachments is where the structure gets lost.
  5. If a spare panel is on the bench, run the copy-to-stick and restore once on it before the remote change. The email route has no undo at distance.

Keep the folder tree whole from email to stick

The restore looks for the files where the transfer wrote them, so the folder goes out whole and lands whole. Extract the zip on the site PC so the original hierarchy returns, then copy the extracted folder to the stick in one operation. Never merge files from two transfers into one folder, and never hand-rebuild the package from individual attachments.

Other HMI software families follow the same rules for a restore from copied folders; one walkthrough covers an HMI project backup restored from a manual folder copy.

Back up the field panel, then restore

  1. At the panel, open system screen > memory > backup and save the current contents to the USB stick. That file is the rollback copy.
  2. Move the backup off the stick to the site PC, or use a second stick, so the incoming package cannot crowd it out.
  3. Copy the extracted transfer package to the stick, whole folders, one operation.
  4. Open system screen > memory > restore and point the panel at the incoming package.
  5. Let the panel restart and load. A project-only restore leaves the firmware as it was; a full package brings the panel back on the version it carried.

If the running project stores recipe files, have the technician copy those off separately too; backing up HMI recipe files before a project download covers that job. Label the backup with the site and the date, and keep it beside the email you sent, because the pair is only useful while it stays together.

Example: a program change to a site running firmware 2.75

Your bench panel runs firmware 2.75 and the project was saved under 2.75. The field technician reads 2.75 on the target panel, which is running the program you are about to replace. The versions match, so the payload is project-only.

Project Transfer to External Memory Device writes the package to your hard drive. In the file manager the exported folder measures 12 MB, an example size; read your real one before sending. The project file inside is startupStorage.eas. The mail cap sits near 25 MB, so the zipped folder attaches with 13 MB of margin and no shared link is needed.

At the site, the technician extracts the zip, saves the running panel to the stick with system screen > memory > backup, moves that backup to the site PC, copies the extracted folder to the stick, and runs system screen > memory > restore. The panel restarts into the new program. The change cost one email and one visit to the panel, and no drive in the post.

The mismatch branch, for contrast: the field panel reads 2.4. The project-only file is now the wrong payload, and the full package carries the OS and firmware. Say it measures 95 MB. That is 95 ÷ 25 = 3.8 times the mail cap, so it goes as a shared-folder link. The stick must hold the measured package with margin: size the stick above the folder you read in the file manager before it leaves the bench. For a panel family whose documentation puts full backups at up to 20 GB, the next standard size up is 32 GB, and that covers the worst case.

Check that it worked

  • The panel restarts into the project you sent: the startup screen loads and a value you recognize moves on it. That last point proves the PLC link as well as the restore.
  • The firmware version on the system screen reads what you intended: unchanged after a project-only restore, the package's version after a full one.
  • A package rejected with an unsupportable hardware version after a USB restore points to a transfer built for another panel family; fixing an unsupportable hardware version after a USB restore takes that message apart.
  • A restore that cannot see the stick at all is a drive question first; testing a USB drive the panel does not recognize gives the order of checks.
  • Archive the emailed package and the site backup together, labeled with the site and date. That pair is the recovery kit for the next change, and it is the same discipline as keeping a master copy against upload protection.

Recommendation: Email a project-only backup only after the field technician has read the panel's firmware version back to you and it matches the version the project was saved under. When the firmware differs or cannot be read, generate the software's full transfer package with the OS and firmware included, send it as a shared-folder link, and have the technician copy the whole folder tree to a stick sized above the package and back up the running panel before restoring.

Questions

Can I edit the backup file before emailing it?

No. Treat a panel backup as a sealed file: the panel reads it back through its restore function and loads the stored data into its memory at startup, and backup files are not editable. If the program has to change, edit the project in the engineering software and generate a fresh transfer package. Keep every name and folder inside the package exactly as the software wrote them, because the restore depends on that structure.

The field panel has no user program on it. Does that change the plan?

It removes the backup step, because there is nothing to roll back to, and it makes the firmware read the whole decision. The technician reads the version on the bare panel's system screen; a match means the project-only file restores, and a mismatch or an unreadable version means the full package loads the firmware along with the program. Note the empty state in your records so the next change at that site starts from the truth.

Can one emailed package update several sites?

Yes, and that is the main reason to send files instead of drives. The firmware check has to pass at every target, so have each site read its version first; one laggard panel takes the full package while the rest take the project-only file. Send each site its own complete folder in its own message, and have each technician send back the backup of the old program, labeled with the site and the date, before you close the job.