On most small HMIs the plastic face is bonded to the touch sensor and display stack, so a cover-only order is usually refused. Check the parts diagram for a listed overlay or digitizer; if none exists, order service or a core exchange with the exact model and serial. Never run the panel with the face off, and never tape a homemade sheet over it as the repair.
The plastic face of a small HMI is not a part you order by size. On most small touch panels the face is laminated to the touch sensor and the display stack, so the vendor sells the assembly or a service job, and a cover-only order is usually refused. A scratched face on a 6-inch panel therefore ends one of two ways: a model-exact overlay or digitizer if the parts diagram lists one for your model, or a core exchange placed with the model and serial in hand. A sheet cut from acrylic is not on that list. This page gives the checks that separate a replaceable overlay from a bonded face, the inspection to run before the panel goes back on the machine, and the package to send the vendor so the order is right first time.
Tell a replaceable overlay from a bonded face
Documentation decides, and the removed piece confirms.
- Read the nameplate and take the exact model number and serial. The parts list, including whether it carries a cover line item at all, is model-specific.
- Open the parts diagram or exploded view for that model. A face drawn as its own line item, named a cover, overlay, digitizer, membrane or keypad, is orderable. A face drawn inside the touch and display assembly is bonded and is not sold loose.
- Look at the piece you removed. A stiff sheet with its own gasket edge or retaining clips came off as a separate cover. A film that tore, or a layer that came away stuck to the sensor glass, is part of a bonded stack.
- Repair-parts sellers list do-it-yourself covers, overlays and digitizers for some panel families. Ask for the seller's drawing and the exact models the part is listed for before buying; a part made for a neighboring model will not seat or seal.
Isolate power before the opening is touched
Safety note: isolate and lock out the panel's power before you remove a face or reach into the opening. Keep it locked out for the whole job; the display stack sits directly behind it, and terminals behind the bezel can stay live with the screen dark.
Inspect the opening with the face off
Keep the power off for this. Give it 15 minutes on the bench with good light, because what you find decides the route:
- Display face: scratches in the display or the sensor glass mean the cover was never the whole fault. The unit goes down the service or exchange route.
- Between the layers: clouds, rings or lifted layers point to liquid entry or adhesive residue. Photograph what you see.
- Gasket groove and bezel: a torn gasket or bent clips will leave a new face unsealed. Put the finding in the order.
- Corners: a hairline crack in the glass grows with handling and panel fitting. Photograph it now, while it still looks harmless.
One finding supports a cover-only order: a clean, unscratched display behind a missing or damaged removable face. Everything else makes it a service or exchange job.
Example: a 6-inch panel with the face already off
Scenario: the scratched face of a 6-inch HMI has been removed, the machine is down, and the display behind the opening looks clean. The operator normally reads this panel from about 2.5 ft away, so small-text sharpness matters as much as the seal.
- The nameplate gives the model and serial. Both are photographed so the numbers cannot be mistyped over the phone.
- The parts diagram for that model draws the face inside the touch and display assembly. No cover line item exists, so there is no part number to order.
- A 15-minute inspection with the power off finds an unscratched display, clean layer gaps and an intact gasket groove. The face is the only casualty.
- The returns desk confirms a core exchange: the damaged unit goes back for credit against a refurbished unit, and the refurbished unit carries the warranty the exchange program states in writing.
The numbers behind the decision: a 6-inch panel read from about 2.5 ft, one parts diagram with no cover line, a 15-minute inspection with the power off, three photographs with the order, one exchange. The machine stays down until the sealed unit is back.
What to send the vendor
If the model has no cover line item, the conversation moves to exchange or repair. Small panels already run wear parts down this route: the backlight lamp exchange path on small panels works the same way, with the same model-and-serial discipline.
Send this with the first message:
- The exact model number and serial from the nameplate.
- Three photographs: the nameplate, the opening with the face off, and the removed face on a clean light surface.
- One line on what happened: the face was scratched, you removed it, and the machine is down or running without a sealed front.
- The questions: is a cover, overlay or digitizer listed as a service part for this model; if not, what does an exchange or repair involve, what credit applies to the damaged core, what warranty covers a refurbished unit, and what has to come back.
Keep the removed face and the panel on the bench until the returns desk says what to ship. The photographs are your record of the condition the unit left in.
Why a homemade sheet fails
The face on an HMI does three jobs, and a cut sheet does none of them:
- Optics: the original face carries the anti-glare finish the panel was designed around. Clear acrylic or polycarbonate adds glare and softens small text at the distance the operator reads, and the anti-glare cover sharpness fix shows how much surface texture sets small-text sharpness.
- Sealing: the bonded face is part of the gasketed front. A taped sheet leaves the opening open to dust, oil mist and washdown water.
- Retention: nothing holds a loose sheet in place over a shift, and a sheet that drops into a running machine is a stoppage.
Do not run the machine with a sheet taped over the opening.
Fit and verify before the panel goes back
- Seat the face or gasket evenly with the power off and check the bezel gap all the way round; a pinched gasket shows as an uneven gap.
- On an exchange unit, confirm the new nameplate matches the model you sent away, load your application, and set the startup screen.
- Power on and check image and touch response across the whole usable area, corners and smallest buttons included.
- If entries mis-register or responses feel slow after reassembly, run the slow touch and update checks before blaming the new face.
- A screen that comes up blank or freezes after fitting is a power question first; the blank and frozen screen checks start at the supply.
The decision, case by case
- Overlay or digitizer listed for your exact model: order the part and fit it to the vendor's instructions, then verify optics and touch.
- Face bonded, display healthy: core exchange or vendor service, ordered with the model, the serial and three photographs.
- Display or sensor damaged: the same service or exchange route; a cover is the wrong part for that fault.
- Unsure which face you have: stop, photograph, and send the model and serial to the vendor before anything ships or sticks.
Recommendation: If the parts diagram for your exact model lists a cover, overlay or digitizer, order that part and follow the vendor's fitting instructions. If it does not, order the exchange: return the damaged unit for credit toward a refurbished one, get the warranty on the refurb in writing before you ship, and keep the machine's screen out of service until the sealed unit is fitted. Send the model, the serial and three photographs with the first message, and keep the removed face until the returns inspection is done.
Questions
Can I buy just the plastic cover for a small HMI?
Usually not. On a small touch panel the face is laminated to the sensor and display stack, so the vendor sells the assembly or a service job. Some panel families do list a cover, overlay or digitizer as a service part, and repair-parts sellers stock them. Before you buy, ask the seller for the part drawing and the exact models it is listed for; a part made for a neighboring bezel will not seat or seal.
What does a core exchange actually involve?
You return the damaged unit, the returns desk inspects it, and the credit goes against a refurbished unit of the same model. Refurbished units from the major core exchange and core credit programs carry their own warranty, commonly one year. Ask what condition rules apply to the returned core, and whether the credit changes if the inspection finds damage beyond the face.
Is a homemade cover ever acceptable?
No. A sheet cut from acrylic or polycarbonate fixes none of the three jobs the face does: it has no anti-glare finish, it leaves the gasketed front open to dust and washdown, and nothing holds it in place over a shift. The fix is the listed part or the exchange unit, with the machine down meanwhile.
The display is scratched too. Is a cover still worth ordering?
A cover is the wrong part there. Scratches in the display or the touch sensor show straight through a new face, and a scored sensor layer can read as dead spots or phantom presses. Photograph the damage with the face off and send it with the model and serial; the vendor will quote service or exchange, not a cover.
Does pulling the face off affect the warranty?
It can. Vendor warranty terms treat the front assembly as sealed equipment, so a removed face changes what a returns desk will accept. Say plainly in your first message that you removed the face and why, and ask before shipping anything. An honest description gets a straight answer about repair, exchange and the return inspection.
Planning information, not legal or engineering advice. Rules differ by place: check codes and permits with your local authority and your licensed trades.