Import your bitmap through the HMI editor's documented symbol-management workflow, then keep the untouched source file in a PC folder your backup already copies. The library entry makes the symbol selectable; the folder makes it recoverable after a workstation swap or a reinstall. Draw each bitmap at the object's exact pixel size, or at a whole multiple of it.
Bring a graphic of your own into an HMI project in two moves: import it through the editor's documented symbol-management workflow, then keep the untouched source file in a PC folder your backup already copies. The import makes the symbol selectable in every project. The folder is what gets it back after a workstation swap or a reinstall, when an entry that lived only inside the editor is gone. Search the installed library first. Editors ship with a large symbol set, and a duplicate of an existing tank or lamp is cleanup work later. This page walks the whole job: sizing the bitmap, importing it, and checking you can recover it.
What you need before you open the library
- The source graphic as an image file your editor accepts. PNG keeps transparent corners; BMP fills the corners with a background color. Check the supported-format list before converting a whole set.
- The object's size in layout pixels. Click the object in the editor and read its width and height properties.
- The editor's help file, installed with the software.
- One folder on the PC that the backup routine already reaches. A machine-assets folder beside the project files works.
Size the bitmap to the object box
Draw the bitmap at the exact pixel size of the object box, one source pixel to one screen pixel. When one master must serve several object sizes, use whole multiples. A 96 x 96 master halves cleanly into a 48 x 48 box. In-between scales split the edges. At 1.5x, some source pixels cover one screen pixel and their neighbors cover two, so straight lines go ragged.
Text inside the symbol obeys the same legibility figure as any panel text: 30 ft of viewing distance per inch of capital height, the FHWA planning figure, and 20 ft per inch when the operator reads it at a glance. Two panels of different sizes can share one layout in pixels, so a symbol drawn for that layout serves both; see why two HMI panel sizes share one layout in pixels.
Add the symbol through the editor's documented workflow
- Search the installed library first, by name and by category. If the graphic exists, use it and stop. If the picture you want already sits on one of your screens, lift it directly: copy a screen bitmap into the HMI object library.
- Copy the source file into the backed-up folder before you touch the library. Never import the only copy from a download folder or a camera card.
- Name the copy after its job and its pixel size, like
lamp_green_48px. A search then finds it years later. - Open the help file that shipped with the editor and search it for symbol management or for adding your own symbols. Some editors put the same steps under the bitmap library menu. Follow the steps printed in your installed help, because the menu path is what differs between versions.
- Import through that documented path, pointing at the copy in the backed-up folder. If the placed object shows a red X, the image file itself is the usual suspect: fix an HMI bitmap import that shows a red X.
- Place the symbol on a test screen at its final object size and confirm it renders.
- Save the project, close it, reopen it, and confirm the symbol still renders. This catches an entry that pointed at a path which only existed during the session.
- Copy the folder to the backup target the same day.
Example: one lamp, two panels
A filler line uses a 15-inch 4:3 panel run on a shift schedule; we publish no duty-cycle rating for these units. A 4:3 diagonal of 15 in is 12 in wide and 9 in high. Read your panel's layout width off the editor and divide: a 12-in-wide 4:3 layout at an XGA-class density works out to 85 pixels per inch (divide the layout's pixel width by 12 in and you get the same figure from its pixel height over 9 in). Use whatever your panel actually reports.
The status lamp object box is 48 x 48 px. Draw the lamp bitmap 48 x 48 px, one pixel to one pixel. If the label lives inside the bitmap, set its capitals at 9 px. The operator stands 3 ft away, and 3 ft ÷ 30 ft per inch = 0.10 in of capital height. That is 0.10 in × 85 px per inch = 8.5, so round to 9 px. For an alarm label read at a glance, use the fast-reading figure: 3 ft ÷ 20 ft per inch = 0.15 in, and 0.15 in × 85 px per inch = 12.75, so 13 px capitals.
A second project reuses the same graphic on a panel whose lamp box is 72 x 72 px. Scaling the 48 px master gives 72 ÷ 48 = 1.5, not a whole multiple, so the edges waver. Draw a second master at 72 x 72 px from the same source art. The folder then holds both, lamp_status_48px and lamp_status_72px, and any future resize request is a re-export, never a redraw.
Keep the source file recoverable
The installed entry and the source file are two different assets:
| Where the copy lives | What it gives you today | What it survives |
|---|---|---|
| Installed library entry | A symbol selectable in projects on that workstation | Only that editor install |
| Source file in the backed-up folder | A rebuild of the entry on any workstation | Every reinstall and PC swap your backups cover |
Set the cadence and write it down: the folder copies to the backup target every 7 days at minimum, and again the same day anything is added. Keep one folder per machine or line. It holds the exported bitmaps and, where you have them, the original drawings from the graphics program, since a flattened bitmap edits badly later. Add a short text note listing which screen and object each file feeds.
Recovery is the import steps above, run again on whatever machine needs them: install the editor, import the sources from the backed-up folder, place, save, reopen. Nothing gets redrawn.
How to check it worked
Run two checks, in this order:
- At the desk: the symbol renders on the test screen at its final size, and the saved project still shows it after a close and reopen.
- Recovery: from the backed-up folder, import the symbol into a scratch project and confirm it renders. Do this once after the first import. It shows the folder alone can rebuild the symbol.
Then download the project to the panel and look from the operator's position, 3 ft in the example above. The lamp reads as a shape and the label capitals clear the 9 px size.
Recommendation: Import through the documented symbol-management workflow whenever your projects pick symbols from the library, and treat the backed-up folder as the master copy. Copy it to the backup target every 7 days and the same day you add a symbol, and keep the original drawing files beside the exports. Never leave a custom graphic existing only inside the library.
Questions
Should the source bitmap be PNG or BMP?
PNG when your editor accepts it. A PNG carries transparency, so the corners of the symbol show the screen background; a BMP fills the whole object box with its background color. Keep the transparent PNG as the master even when a project needs a BMP copy, and check the editor's supported-format list before converting a whole set of graphics.
How often should the symbol folder be backed up?
Copy it to the backup target every 7 days at minimum, and again the same day you add or redraw a symbol. Tie the folder to the project backup so one job covers both. Before you close out the week, open the backup target and confirm the newest file's date matches the newest file in the folder.
What happens to installed symbols when the engineering PC is replaced?
Plan for the library staying behind on the old machine. Install the editor on the new PC, then re-import the sources from the backed-up folder through the same symbol-management steps. Keep the old machine reachable until every symbol in a reopened project renders. That final render check is the sign the migration finished.
Should I keep the original vector drawing too?
Yes. Keep the drawing-program file beside the exported bitmap, with the shapes still editable. A flattened bitmap resizes and recolors badly, and a redraw request usually arrives years later, when nobody remembers the font or the colors. The folder then holds the editable original and the pixel-exact export, so a size change becomes a re-export.
Planning information, not legal or engineering advice. Rules differ by place: check codes and permits with your local authority and your licensed trades.