The terms
A
- Active area
- The part of the screen that shows a picture, smaller than the outside of the unit. Listed per size in the size guide.
- All-in-one
- A display with its computer inside the same case. Ours has an RK3568 Android computer.
- Andon
- A visual signal of production status. See the andon guide.
- Android
- The operating system on these units. It is why you can install your own app.
- Aspect ratio
- Width against height. Most of our screens are 16:9. The 10.1 inch is 16:10.
B
- Bezel
- The frame around the picture. On our units it is part of the metal front.
C
- Class 2
- A power-limited class of low-voltage circuit in the US electrical code. Ask your electrician if it applies to your supply.
- CMS
- Content management system. Software for scheduling and pushing content to screens, usually a paid cloud service.
- Contrast ratio
- How far apart white and black sit on a panel. Ours run from 600:1 to 1000:1 by size.
- Cut-out
- The opening in a wall or panel for a flush mount. See the cut-out table.
D
- Daypart
- Running different content at different times of day. Our player has on and off hours but no dayparting.
- DC terminal adapter
- The small adapter in the box. Your two power wires land on its screw terminals, and it plugs into the unit.
E
- exFAT and FAT32
- The formats most cards use. Both work. FAT32 limits one file to 4 GiB.
F
- Flush mount
- A screen set into a wall, so only the front shows.
G
- GLB
- A 3D model format for viewing. We offer one per size on downloads.
H
- H.264
- A video compression format, also known as AVC. The safe choice for signage video.
- H.265
- A newer video format, also known as HEVC, and common on phones. Support depends on the unit.
- HDMI out
- A video output. On these units HDMI does not take a signal in.
- HEIC
- The default photo format on many iPhones. The player does not read it.
- HTTPS sync
- Our player's optional way to pull new content from your own web server on a timer.
I
- Internal copy
- The copy of your show the unit keeps in its own memory, so the card can come out.
- IP65
- An ingress protection code under IEC 60529: 6 means dust-tight, 5 means protected against water jets. On these units it covers the front face only.
L
- Legibility distance
- How far away text can be read. We use 30 feet per inch of capital height.
M
- Manifest
- The small file that lists what a screen should download when it syncs.
- microSD
- The small memory card used in the unit's card slot.
- MP4
- A video file type. Use it with H.264 video inside.
N
- Nit
- A unit of screen brightness, one candela per square meter. Ours run 250 to 400 nits as standard.
P
- Panel mount
- Mounting through a cut-out in a panel, with the unit held from behind. Ask us about clamps for your panel.
- Pixel pitch
- The physical size of one pixel. It sets how large a given text height looks on each screen.
- PoE
- Power over Ethernet: power and data on one cable. These units do not support it.
- Portrait
- A screen turned tall. On these units it is a rotation setting on the same hardware.
- Proof of play
- A report of what played and when. Advertisers often want it. Our player does not produce it.
R
- RK3568
- The processor in each unit.
- RS232
- An older serial port, still common on industrial equipment. Each unit has one.
S
- Staff PIN
- The code that opens the player's hidden menu.
- Static power
- The power figure on the spec sheet, 18 W for every size. Allow more for startup.
- STEP
- A 3D CAD file format. Use it to check your wall or millwork against the real unit.
- Sunlight-readable
- A brighter panel option for bright rooms and glass walls. Not an outdoor rating.
T
- Traveling cable
- The flexible cable that hangs between an elevator car and the building.
V
- VESA
- A standard pattern of mounting holes. Our drawings show 75 x 75 and 100 x 100 mm. They mark the holes M4 on every size except the 18.5 inch, where we will confirm it on your order.
- Viewing angle
- How far off center a screen stays readable. Listed four ways, because the four can differ.
- Voltage drop
- The voltage lost along a cable. See the power guide.
Questions
What does nits mean on a display?
A nit is a unit of brightness, one candela per square meter. Our standard panels run from 250 to 400 nits, depending on size.
What does IP65 mean?
Under IEC 60529, 6 means dust-tight and 5 means protected against water jets. On our units it applies to the front face only.
What is proof of play?
A report showing what played and when. Advertisers often ask for one. Our free player does not produce it.