Remap a USB serial adapter COM port when software stops at COM4

7 min read · Published November 7, 2026

Panel programming software that stops its serial list at COM4 cannot open an adapter Windows assigned to COM8. Remap the adapter to an unused port from COM1 through COM4 in Device Manager's Advanced settings, reopen the software, and select that number. No PLC-side setting changes.

Panel setup software that stops its serial port list at COM4 cannot open a USB serial adapter that Windows named COM8. You do not extend that list; you move the adapter into it. Device Manager lets you assign any free COM number to the adapter. The fix is to pick an unused port from COM1 through COM4, close the dialogs, reopen the panel software, and select that number. The change is PC-side only: the panel project, the PLC settings, the cable and the wiring stay as they are. The whole job takes about 5 minutes at the bench. This page walks the remap step by step, shows how to pick a number that is actually free, and lists what to check at 9600 baud when the port opens and the link still fails.

Why does the panel software only list COM1 to COM4?

The list is fixed in the software. It offers four serial names, COM1 through COM4, and nothing inside the program extends it, so an adapter Windows named COM8 cannot be selected.

The number after COM is a label Windows hands the adapter when it detects it. Your PC had already handed out seven names, so the adapter took the eighth. Windows itself has no four-name limit; the software does. It was written with four slots in its port picker and ships no setting that widens them, so the fix lives on the PC side.

Match your symptom to its cause before you touch anything:

  • The software's port list shows COM1 to COM4 and nothing else: the program's fixed picker, with no adapter fault and no missing driver behind it.
  • The same adapter talks to the PLC from a terminal program on COM8: the adapter, cable and wiring are good, and the picker is the only barrier.
  • A number inside COM1 to COM4 is missing or greyed in the drop-down: another device on this PC holds that name right now.
  • There is no Ports (COM & LPT) section in Device Manager at all: Windows has not detected the adapter, and detection comes before any remap.

How do I remap the USB serial adapter to a port in COM1 to COM4?

Open the adapter's properties in Device Manager, choose the Port Settings tab, open Advanced, and pick an unused number from COM1 through COM4 in the COM Port Number drop-down. Close the dialogs and write the number down.

  1. Close the panel software, so it rebuilds its port list when it reopens.
  2. Plug the adapter in, open Device Manager, and expand Ports (COM & LPT).
  3. Right-click the adapter's entry and choose Properties.
  4. Open the Port Settings tab and click Advanced.
  5. In the COM Port Number drop-down, choose a number from COM1 to COM4 that no other entry holds.
  6. Click OK on every open dialog. If Windows asks you to reconnect the adapter, unplug it and plug it back.
  7. Reopen the panel software and select the number you assigned.

This is the documented route in Windows itself: Properties, Port Settings tab, Advanced, then the new number. No download, script or driver change is involved.

Check it worked: Device Manager shows the new number in brackets after the adapter's name, and the panel software's list now contains it. If the number snaps back to COM8, another device claimed it in the meantime; pick a different one.

How do I open Device Manager and find the adapter?

Press the Windows key, type devmgmt.msc, and press Enter. The adapter sits under Ports (COM & LPT) with its current number in brackets after its name, so confirm the name before you change anything.

Confirm the entry by pulling the adapter out of its USB socket and watching which entry disappears, then putting it back. The test takes about 10 seconds. With a scanner, a scale and a printer sharing one PC, it stops you remapping the wrong device.

If there is no Ports (COM & LPT) section, choose View, then Show hidden devices, and look again. An adapter that stays invisible has a detection or driver problem, and the remap waits until Windows sees it; a walkthrough on restoring missing COM ports in Windows Device Manager covers that side of the job.

Which COM number is safe to pick?

Pick a number in COM1 through COM4 that no other entry in Ports (COM & LPT) holds. With four names in the list, check each of the four before you choose, because a number another device owns will fail when the panel software opens it.

A safe pick meets three conditions at once: it sits inside the software's range, no entry under Ports (COM & LPT) holds it, and no running program is using it when the panel software opens the port. Terminal programs, data loggers and other panel tools all count, so close them before the first test. A number another program holds fails at the open step, the same conflict behind a SCADA connection to a PLC when an HMI panel holds the port.

If all four names are taken, free one: unplug the device that holds it or remap that device upward, then take its old name for the panel adapter. The picker's range is the constraint, so one of the four has to become free.

Example: the adapter sits on COM8 and the list stops at COM4

Say the adapter sits on COM8, other devices already hold COM1 and COM3, and COM2 and COM4 are unassigned. The software's four-name list leaves 2 candidates, you assign COM2, verify it in Device Manager, and select COM2 in the software. The bench PC sits next to the panel, so the 2 m serial cable is no concern; at 9600 baud an RS-232 link of this length is well inside the roughly 15 m the signalling is generally considered dependable over.

The bench PC's Ports (COM & LPT) list reads:

Name Held by Open for the panel software?
COM1 Built-in serial port, feeding a scale no
COM2 Nobody yes
COM3 Second USB adapter, feeding a barcode scanner no
COM4 Nobody yes, spare
COM8 The panel adapter outside the picker

Four names sit in range and two are held, so two are open: 4 - 2 = 2 candidates. Take the lowest, COM2. Right-click the adapter's COM8 entry, open Port Settings, then Advanced, choose COM2 in the COM Port Number drop-down, and click OK. The entry now reads COM2. Reopen the panel software, select COM2 from its list, and start the download; the software opens COM2 at 9600 baud, 8 data bits, no parity and 1 stop bit, and a small panel project transfers in well under a minute. If the transfer starts and then dies, the name is no longer the problem and the serial settings are, which the next section sorts out.

If the software opens the number and the link still fails, the mapping is fixed and the fault sits in the serial settings or the cable. The common default for PLC and panel links is 9600 baud with 8 data bits, no parity and 1 stop bit, so start there.

Work the checks in this order:

  1. Same name on both sides: the software's selection and the brackets in Device Manager match exactly.
  2. Port free: every other program that talks serial is closed, because a held port fails at open.
  3. Parameters match: set 9600 baud, 8 data bits, no parity and 1 stop bit, the default most PLC and panel links ship with, then correct whatever the panel's own document prints differently.
  4. Com light: if the light on the adapter stays dark while the software tries, the link is not closing electrically; the HMI to PLC serial timeout with a dead com light checklist starts at the connector.
  5. Transfer dies partway: timings and drivers move to the front there, and the USB serial adapter timeout when programming a text panel article covers that case in detail.

How do I keep the number from changing later?

The number you assign stays with that adapter on that PC. A move to a different USB socket or a driver update can bring it back on a new one, so check Ports (COM & LPT) after any change and keep one socket reserved for the panel adapter.

An ordinary reboot brings the same number back. The two events that move it are the adapter going into a different USB socket and a driver reinstall. devmgmt.msc shows the current number in one glance, so open it after any hardware or driver change and compare against the setup sheet before you blame the panel project. Put the number on the sheet, label the cable, and leave the panel adapter in its own socket.

Recommendation: remap the adapter at the bench, before the PC goes on the machine. Pick the lowest free number in COM1 to COM4, write it on the panel's setup sheet, dedicate one USB socket to the adapter, and recheck the number in Device Manager after any driver update or socket change. Leave the PLC-side settings untouched: the remap changes a PC-side name and nothing else.

Questions

Why does the same adapter show a different COM number on two PCs?

The number depends on what each PC had already detected. On the office desktop, with one internal serial port, the adapter lands on COM2; on the line PC, which has seen several USB serial devices, the same adapter lands on COM8. Remap it on the PC it will serve and write that PC's number on the setup sheet, because the assignment does not travel with the adapter.

Why did the adapter come back on COM9 after I moved it to another USB socket?

Windows can treat the adapter in a new socket as a new device and hand it the next free number, often COM9 or higher. Plug the panel adapter back into the socket you remapped it on, or open Device Manager after the move and remap it again. The panel project never needs to change.

Can two devices use the same COM number?

Not at the same time. Windows accepts an assignment that collides with a device that is unplugged at that moment, but when both devices are present one of them fails to open. That is why the procedure checks every entry under Ports (COM & LPT) before you choose: take a name no entry currently holds.

Do I need to reinstall the adapter driver to fix this?

No. Changing the COM number edits the adapter's properties; the driver stays installed and the adapter keeps working in other programs. Reinstall a driver only when the adapter is missing from Device Manager or shows as an unknown device, because the remap needs a detected device before the Port Settings tab offers anything.

Planning information, not legal or engineering advice. Rules differ by place: check codes and permits with your local authority and your licensed trades.

Keep reading

Build your signAsk for a quote